GROUND SCAN
Line No
Step No
Search Value
After each line of the scanning process is
completed, you will see an alert on the screen
which means you have to start a new scan
line.
Change your position to the beginning of the
next line and then press the start button
located under the handle of the device.
On the screen appears a window that includes
a grid of cells according to the number of lines
and steps previously set.
In the right pane, you can see information
about the current step, current scan line and a
numeric value of the probe during the
scanning process
When the scanning process is completed, you
will see an alert on the screen stating that the
scanning process is complete, press OK to exit
During the scanning process, you will see the
color change of each cell of the grid according
to the current scan point according to different
colors. The user can know whether there is a
target under the scanned ground or not by the
color of each cell.
Red
: gold or large pieces of metal target
Green
: nornal natural ground
Light Blue
: a small cavity
Blue:
a larg voids
like a tunnel
Yellow
: a small piece of metal object
25
Notice
In Ground scan system, the device was
provided with a special technology, which
is the possibility of full control of scan
process through the Multi Visual Analyzer
app. for more iformation folow Multi
Visual Analyzer description on this user
manual