2
D1010-054 / 056/ 057
- mV to mA Converter
G.M. International ISM0098-8
General Description:
The single channel DIN Rail mV to mA converters, D1010S-054, D1010S-056, D1010S-057, convert a mV signal from sensors located in Hazardous Area,
and repeat the current in floating circuit to drive a Safe Area load.
Function:
1 channel I.S. analog input, provides 3 port isolation (input/output/supply) and current (source) output signal.
Signalling LED:
Power supply indication (green).
EMC:
Fully compliant with CE marking applicable requirements.
Supply:
24 Vdc nom (20 to 30 Vdc) reverse polarity protected, ripple within voltage limits
≤
5 Vpp.
Current consumption @ 24 V:
40 mA with 20 mA output typical.
Power dissipation:
0.9 W with 24 V supply voltage and 20 mA output typical.
Max. power consumption:
at 30 V supply voltage and overload condition 1.2 W.
Isolation (Test Voltage):
I.S. In/Out 1.5 KV; I.S. In/Supply 1.5 KV; Out/Supply 500 V.
Input:
-5 to +55 mV for D1010S-054;
-5 to +35 mV for D1010S-056;
-5 to +10 mV for D1010S-057;
Output:
4 to 20 mA, on 250
Ω
load in source mode.
Response time:
25 ms (10 to 90 % step change) with 8.6 dB of NMRR.
Common mode rejection:
better than 80 dB.
Output ripple:
≤
20 mVrms on 250
Ω
load.
Burnout:
Upscale in 25 ms.
Performance:
Ref. Conditions 24 V supply, 250
Ω
load, 23 ± 1 °C ambient temperature.
Calibration accuracy:
≤
± 0.1 % of full scale.
Linearity error:
≤
± 0.1 % of full scale.
Supply voltage influence:
≤
± 0.02 % of full scale for a min to max supply change.
Load influence:
≤
± 0.02 % of full scale for a 0 to 100 % load resistance change.
Stability:
estimated degradation in 3 years
≤
± 0.47 % least sensitive range.
Compatibility:
CE mark compliant, conforms to 94/9/EC Atex Directive and to 2004/108/CE EMC Directive.
Environmental conditions:
Operating:
temperature limits -20 to + 60 °C, relative humidity max 95 %.
Storage:
temperature limits – 45 to + 80 °C.
Safety Description:
II (1) G [Ex ia Ga] IIC, II (1) D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I, II 3G Ex nA II T4, [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I associated electrical apparatus.
Uo/Voc = 1.1 V, Io/Isc = 38 mA, Po/Po = 11 mW at terminals 15-16. Ui/Vmax = 30 V, Ii/Imax = 104 mA, Ci = 1.05 nF, Li = 0 nH at terminals 15-16.
Um = 250 Vrms, -20 °C
≤
Ta
≤
60 °C.
Approvals:
DMT 01 ATEX E 042 X conforms to EN60079-0, EN60079-11, EN60079-26, EN61241-0, EN61241-11,
IECEx BVS 07.0027X conforms to IEC60079-0, IEC60079-11, IEC60079-26, IEC61241-0, IEC61241-11, IMQ 09 ATEX 013 X conforms to EN60079-0, EN60079-15,
Mounting:
T35 DIN Rail according to EN50022.
Weight:
about 110 g.
Connection:
by polarized plug-in disconnect screw terminal blocks to accommodate terminations up to 2.5 mm
2
.
Location:
Safe Area or Zone 2, Group IIC T4 installation.
Protection class:
IP 20.
Dimensions:
Width 22.5 mm, Depth 99 mm, Height 114.5 mm.
Technical Data
Characteristics