GB
11
Problem
Possible cause
Solution
No function when On/Off Trigger Switch (1) is operated
Lock-Off Button (2) not depressed
Depress the Lock-Off Button before pressing the On/
Off Trigger Switch
Defective On/Off Trigger Switch
Replace the On/Off Trigger Switch at an authorised
GMC service centre
Water does not flow when Coolant Valve (20) is
operated
Coolant Hose (22) blocked
Remove hose and unblock
Water mains tap not open
Carefully open tap
Mains water hose does not stay connected to Water
Hose Connector (23)
Mains pressure too high
Only slightly open mains water tap
Coolant Valve (20) closed
Open Coolant Valve
Incompatible hose (diameter, material, shape)
Use different mains water hose, use adaptor, or secure
connection with hose ties or jubilee clip
Troubleshooting