background image

13

Bolt cutout

Latch cutout

Contour for striking plate recess

Material thickness 3 mm

The lock and corresponding striking plate are a matching system which has been te-
sted and approved according to the appropriate standards. Therefore, the HZ-lock VB 
19000 may only be used in combination with a matching striking plate from Glutz. 
If the HZ-lock VB 19000 is used with a third-party striking plate, Glutz AG cannot 
guarantee the fault-free functionality of the lock.

Summary of Contents for HZ-lock VB 19000

Page 1: ...MA 10101 Assembly and Maintenance Instructions HZ lock VB 19000...

Page 2: ......

Page 3: ...sembly instructions 14 HZ lock VB 19000 multipoint lock 15 Assembly requirements 16 Switching the panic function 18 Removing the panic function 19 Check of electrical feedback 19 HZ lock VB 19000 with...

Page 4: ...ly maintenance care and disposal Please read this manually carefully and attentively prior to installation Save this manual for as long as the product is in use and pass it along to the next user The...

Page 5: ...installed at a height of 900 mm to 1100 mm above the surface of the finished floor with the door closed If the majority of the door users are small children a lowering of the actuation bar height shou...

Page 6: ...150 N to the lever handle in the actuation direction Do not actuate the lever handle and key at the same time Do not drill in the lock area of the door leaf with installed lock Do not use force to st...

Page 7: ...must be replaced Do not carry the door leaf by the lever handle Locks must be lubricated at least 1 x per year according to the manufacturer s specifications use grease or non resinating oil Once ther...

Page 8: ...ial free switchover contact for mechanical handle coupling via the cylinder Bolt position contact and leaf position contact for monitoring of the correct locking the evaluation of these contacts is st...

Page 9: ...ility for door elements up to RC4 Three blocked bolts with 20 mm forward feed Hardened lock case anti drilling protection Hardened bolts Hardened connecting bars for the additional bolts Connecting ba...

Page 10: ...pair the automatic locking Therefore moni toring the correct locking is recommended for automatically locking locks HZ lock VB 19000 locks are normally equipped with panic function In this process the...

Page 11: ...maintenance The lock latch control latch and the bolts must be lubricated with suitable lubricants e g MOTOREX 176 GP multi purpose grease at least twice annually or more frequently depending on use...

Page 12: ...a matching system which has been te sted and approved according to the appropriate standards Therefore the HZ lock VB 19000 may only be used in combination with a matching striking plate from Glutz I...

Page 13: ...th three bolts every time it is closed The key rotation in the cylinder is therefore unnecessary However in order for the automatic blocking to take place in a fault free manner the bolts and the latc...

Page 14: ...ight pressure and carefully pull apart without bending Monitoring contacts for 1 Bolt position 2 Leaf position 3 Lever handle contact 4 Cylinder contact Reversible panic direction EN 179 for door leaf...

Page 15: ...coil voltage 12 or 24 VDC Control and handle contacts locking contacts Monitoring contacts Inside outside lever handle Door position Door locking Entry with key Quality standard RC4 in accordance with...

Page 16: ...ower lock section and the upper forend extension takes place by carefully pushing one of the two connecting bars of the forend extension into the guide grooves on the forend of the main lock until the...

Page 17: ...te to drill the holes for the screw connection of the in side and outside plate is recommended The site fixing template is positioned on the lever handle and the cylinder cutout Drill from both sides...

Page 18: ...does not fall into the lock case 5 The lever handle can now be released again 6 Rotate the lock handle follower now disengaged at the top 7 RemovetheroundstickerwithHZsymbolnexttothefollower whichwill...

Page 19: ...st A clarifying telephone conversation is normally less expensive than a lock repair Check of electrical feedback The following are requirements for the correct function of the door monitoring bolt po...

Page 20: ...ck control In an emergency the escape door strike can be unlocked by the fire alarm system or disengaged with the emergency button The cylinder contact installed in the lock can be used for the unlock...

Page 21: ...lever handle is disengaged and the door can no longer be ope ned with the inside lever handle In order to guarantee the ability to exit despite this an exit button is arranged on the inside on a prote...

Page 22: ...striking plate brass case with adjustable magnet position 2698 Flat permanent magnet with cap profile for striking plates made of non magnetic stainless steel 2697 10 mm round magnet height 5 mm For d...

Page 23: ...9 169 209 209 26 324 190 190 190 209 97 24 2 8 12 11 6 128 209 269 209 209 A B 2050 773 1005 2150 873 1105 2250 973 1205 Glutz AG Massblatt HZ Lock mit Tagesfunktion Zsm 23 05 13 X X X X 24 Auxiliary...

Page 24: ...llungs kontakt Zusatzmagnet f r Tagesbetrieb Option 25 Connection diagram white 1 brown 2 green yellow 4 grey 5 pink 6 blue 7 red 8 black 9 violet 10 grey pink 11 red blue 12 white green 13 brown gree...

Page 25: ...ntact closes with an actuation of the lever handle pointing to the left For example signalling of the authorised exit on the monitoring system 9 black NO 30 300 Lever handle con tact This contact clos...

Page 26: ...1 The control latch is jammed 2 There is lubricant or oil spray in the lock 3 The control latch is bent 1 Lightly grease and move the control latch by pressing the main latch in slightly 2 Send the lo...

Page 27: ...3 Send the main lock in for repairs 4 Fit an original striking plate or ma gnet 2 2 The Electrical connection dis engaging switchover contact does not function only for locks with this option until Ju...

Page 28: ...r doors on escape routes fulfilled 70N unloaded Durabilty of ability to release against aging and degradation for doors on escape routes fulfilled 200 000 cycles Initial test carried out and Classific...

Page 29: ...t is easily removed Glutz AG Segetzstrasse 13 4502 Solothurn Schweiz Tel 41 32 625 65 20 Fax 41 32 625 65 35 info glutz com www glutz com Glutz Deutschland GmbH Schmalenhofer Strasse 61 42551 Velbert...

Reviews: