Installation requirements
13
Installation requirements
WARNING:
The equipment must be installed in restricted access locations only.
NOTE:
Check the delivery route to the installation location for necessary clearance and remove all
obstructions.
Heating and ventilation
Provide a heat and ventilation system capable of maintaining room temperature between 17°C (63°F) and
25°C (77°F) and a relative humidity (non condensing) of min. 40% and max. 60%.
For heat emission see "Power consumption" on page 1.
Installation kit
Installation kit is included with the equipment. It comprise the parts necessary to make the installation.
Ord. code
Name
Quantity
10104022
FRESH, SOLVENT, LEVEL, SENSOR, COMPLETE
1 pc
10066844
CASTROL SPHEEROL 4601 GREASE
1 pc
10104023
DIRTY, SOLVENT, LEVEL, SENSOR, COMPLETE
1 pc
10104014
CABLE, EXT, PUMP, CONTROL, FLEX-i-PRO
1 pc
0-BA-057
SA, INLET, SOLVENT, EXTERNAL, BARREL
1 pc
0-BA-058
SA, OUTLET, SOLVENT, EXTERNAL, BARREL
1 pc
5-DP-003
KEY LOCK TRIANGLE
1 pc
5-FA-027
HOSE, AIR EXHAUST D140
5 m
5-FA-021
TUBE, POLYURETHANE D4 × 6
5 m
7-HA-010
HOSECLAMP 122-142
2 pcs
1-330-029
SAFETY TANK
1 pc
10103482
SA, OUTLET, SOLVENT, EXT, LINK
1 pc
Floor stability
WARNING:
Note the very heavy weight of the equipment!
Please refer to weight and dimensions of the equipment when calculating footprint and load for
preparation of the installation site.
The floor should have a variation in height of no more than 6 mm per meter (1/4” over 40” length). If in doubt
about the floor loading, please consult a structural engineer.
May, 2022
Pre-installation Guide
|
Flex-i-Line 520 (XP) Dry/Compact/Standard/Max
Summary of Contents for Flex-i-Line 520
Page 2: ...2 Blank Pre installation Guide Flex i Line 520 XP Dry Compact Standard Max May 2022 ...
Page 6: ...Pre installation Guide Flex i Line 520 XP Dry Compact Standard Max May 2022 ...
Page 12: ...Pre installation Guide Flex i Line 520 XP Dry Compact Standard Max May 2022 ...
Page 20: ...Pre installation Guide Flex i Line 520 XP Dry Compact Standard Max May 2022 ...