GLP
German Light Production
(V1.6)
17
3.10.9 Default Settings
(DFSE)
DFSE
Press
Enter
to reset all fixture personalities (not the adjusted functions) to
the default values. On the display will appear
ok
to indicate that the de-
faults are set.
Function
Display
Default Settings
DMX Address
D001
D001
Pan reverse
RPAN
ON
OFF
9
Tilt reverse
RTLT
ON
OFF
9
Automatic lamp on
LAAU
ON
OFF
9
Lamp on via DMX
DLOF
ON
9
OFF
Display
DISP
D ON
9
Cooling fan
FANS
HIGH REG
9
LOOF
LOHI
Feedback
FEED
ON
9
OFF
3.10.10 Feedback
(FEED)
FEED
The
Y
Y
P
P
O
O
C
C
2
2
5
5
0
0
is provided with a automatic position correction (feedback)
for the Pan and Tilt movement. Use the
Up/Down-
keys to select
ON
if you
want to enable the feedback function or
Off
if you don't want this function.
Press
Enter
to confirm or
Mode
to cancel and return to the menu.
3.10.11 Correction of faults
(EFLG)
EFLG
(Function available for authorized persons only)
3.11 Error and Information Messages
HEAt
This message appears if you try to switch on the lamp within 5 minutes
after having switched off (lamp too hot). The message will appear on
the display if the lamp doesn’t ignite within 20 seconds. The fixture will
store this command and automatically ignite the lamp after 5 minutes.
LaeR
After the ignition of the lamp was two times not successful the display
will show
LAER
. That means the lamp could be damaged or even
missed, the fixture is overheating or there could be a failure on the