GLP
German Light Production
(V1.6)
16
80°C are not critical. 80°C and more lead the lamp being switched off at a
critical point. Please note for a save operation that the outside temperature
should not exceed 45°C.
3.10.7 Fan Control
(FANS)
FANS
By using this function you can choose between 4 types of fan speed
operations. Use the
Up/Down-
keys to select desired function and press
Enter
to confirm or
Mode
to cancel and return to the menu.
HIGH
The cooling fan works continuously at max. speed.
REG
The fan automatically raises its speed in order to control inside
temperature of the fixture.
LOOF
The fan keeps the adjusted low speed until the temperature
exceeds max. inside temperature, then the
Y
Y
p
p
o
o
c
c
2
2
5
5
0
0
automatic-
ally
switch off
the lamp.
LOHI
The fan keeps the adjusted low speed until the temperature
exceeds max. inside temperature, then the
Y
Y
p
p
o
o
c
c
2
2
5
5
0
0
automatic-
ally switch from low to high fan speed.
3.10.8 Adjustments and Calibrations
(ADJU)
ADJU
By this function you can adjust and calibrate the positions of the different
wheels and other motors. This can be necessary after a service or repair
work.
For this function you have to entry the fixture code. This work should be
done only by authorized persons.
Use the
Up/Down-
keys to select desired function and press
Enter
to
confirm or
Mode
to cancel and return to the menu. Use now the
Up/Down-
keys to set the adjustment values and confirm once more with the
Enter-
key or cancel with the
Mode-
key.
Function
Value
Remark
COLO
- 99 - + 99
Color wheel
GOBO
- 99 - + 99
Gobo wheel
PRIS
- 99 - + 99
Prism wheel
SHT1
- 99 - + 99
Shutter 1
SHT2
- 99 - + 99
Shutter 2
clre
Adjustments in the internal circuit.