17
(instruction version 0.91)
GLP
z
German Light Production
5 Change the Lamp
For a frictionless operation please read this chapter carefully and follow all instructions.
5.1 Safety
Regulations
•
Pull out the main plug!
•
Wait min. 20 minutes after the last operation to cool down the fixture.
•
Don’t touch the bulb of the lamp with bare fingers (this can cause damages).
•
Before you put the
J
J
U
U
N
N
I
I
O
O
R
R
S
S
C
C
A
A
N
N
3
3
into operation close the casing, otherwise
your retina can be hurt!
5.2 Realize the Lamp Change
Please have also a look at Figure 1-1 on page 4.
1.
Pull out the main plug!
2. Open the two Phillips screws on the bottom side of the unit.
3. Release carefully the lamp holder plate from the duct where the lamp is
mounted on.
4. Replace the old lamp. (Don't touch the glass bulb of the lamp with bare fingers).
5. Put the lamp holder plate carefully back in the duct.
6. Close the two Phillips screws again.
7. Adjust the optimum position of the lamp with the three adjustment screws on the
lamp holder sheet.
Attention: Pay attention on a firm fit of the lamp!
6 Change a Gobo
The
J
J
U
U
N
N
I
I
O
O
R
R
S
S
C
C
A
A
N
N
3
3
is fitted with standard gobos (outside diameter 25 mm, image
size 17 mm). You can use ether steel or glass gobos.
Gobo thickness: ~0,15 mm (stainless steel) or ~1,1 mm (glass)
6.1 Safety
Regulations
•
Pull out the main plug!
•
Wait min. 20 minutes after the last operation to cool down the fixture.