background image

 

 

 

13

 

(instruction version 0.91)

 GLP 

z

 

German Light Production

 

3.9.7 Default Settings 

(DFSE)

 

DFSE

 

 

Press 

Enter

 to reset all fixture personalities (not the adjusted functions) to 

the default values. On the display will appear 

ok

 to indicate that the defaults 

are set. 

 

Function 

Display 

Default Values 

DMX Address 

D001 

D001 

Pan reverse 

RPAN 

ON 

OFF

  

9

 

Tilt reverse 

RTLT 

ON 

OFF

  

9

 

Automatic lamp on 

LAAU 

ON 

OFF

 

9

 

Lamp on via DMX 

DLOF 

ON

 

9

 

OFF 

Display  

DISP 

D ON

 

9

 

REV 

Cooling fan 

FANS 

HIGH  REG

 

9

 

LOOF  LOHI 

 

3.9.8  Correction of faults 

(EFLG)

 

 

 

(Function available for authorized persons only) 

3.10  Error and Information Messages

 

 

HEAt 

This message appears if you try to switch on the lamp within 5 minutes 
after having switched off (lamp too hot). The message will appear on 
the display if the lamp doesn’t ignite within 20 seconds. The fixture will 
store this command and automatically ignite the lamp after 5 minutes. 

LaeR 

After the ignition of the lamp was two times not successful the display 
will show 

LAER

. That means the lamp could be damaged or even 

missed, the fixture is overheating or there could be a failure on the 
igniter or ballast. Switch off the power supply and solve the possible 
problem.  

OTMP 

This error message informs you that the fixture was overheating and 
that the relay switches off the lamp. Pleas look for possible reasons (fan 
faulty, air in/outlets blocked or very dirty, lamp broken or very old, too 
high ambient temperature. Switch off the power supply and solve the 
possible problem. 

RsER 

This message informs you that one of the fixture function wasn’t able to 
do its reset correct (magnetic sensor, stepping motor, driver on the 
PCB, cables, etc.). Repair the defect and start the fixture again. 

EFLG

 

Summary of Contents for Junior Scan 3

Page 1: ...Instruction Manual from software version 1 0 instruction version 0 91 email service glp de Internet http www GLP de...

Page 2: ...1 instruction version 0 91 GLP z German Light Production This side is intentionally unlabelled...

Page 3: ...ust the DMX Address D001 8 3 2 The Test Program TEST 8 3 3 The Audio Program AUDI 8 3 4 Lamp On Off LAMP 9 3 5 Reset RESE 9 3 6 Running time of lamp and unit TIME 9 3 7 Invert Pan Movement RPAN 9 3 8...

Page 4: ...hange 17 6 Change a Gobo 17 6 1 Safety Regulations 17 6 2 Realize the Gobo Change 18 7 Maintenance and Cleaning the J JU UN NI IO OR R S SC CA AN N 3 3 18 7 1 Safety Regulations 18 7 2 Circumference a...

Page 5: ...GLP z German Light Production instruction version 0 91 4 1 Description of the Device Display Data entry Lens Relay bracket Air outlet 2x Air inlets Casing screws Figure 1 1...

Page 6: ...AC before you open the J JU UN NI IO OR R S SC CA AN N 3 3 Please do not touch the bulb of the lamp if you are not absolutely sure it is cold Danger of BURNING 5 Never look directly into the beam of t...

Page 7: ...you have to use a stipulated safety wire that can hold at least 10 times the weight of the fixture Install it through the handle and connect it with the truss support Pay attention to a safe and prope...

Page 8: ...program SVPT Basic position for the audio program SIZE Size for the audio program NORM BIG MID SMALL LAMP Switch on of the lamp direct at the Y YP PO OC C 2 25 50 0 RESE Reset TIME POWR Running time...

Page 9: ...the display shows OK or press the Mode key to cancel The DMX Address is stored also while switching off the J JU UN NI IO OR R S SC CA AN N 3 3 3 2 The Test Program TEST Test The Test program allows y...

Page 10: ...the shutter is closed at the same time Use an external controller or the manual drive mode see also chapter 3 9 1 on page 10 3 5 Reset RESE RESE Press the Enter key to run a reset of all fixture funct...

Page 11: ...NU This function allows you to drive all the fixture functions manually Select the desired function with the Up Down keys and confirm with Enter Now choose the desired value with the Up Down keys and...

Page 12: ...he lamp via DMX or not Use the Up Down keys to select ON if you want to switch off the lamp via DMX or Off if you don t want this function Press Enter to confirm or Mode to cancel and return to the me...

Page 13: ...he different wheels and other motors This can be necessary after a service or repair work For this function you have to entry the fixture code This work should be done only by authorized persons Use t...

Page 14: ...n the display if the lamp doesn t ignite within 20 seconds The fixture will store this command and automatically ignite the lamp after 5 minutes LaeR After the ignition of the lamp was two times not s...

Page 15: ...2 23 13 5 Color 9 UV blue fast 36 37 24 25 14 3 Color 9 Color 10 fast 38 39 26 27 15 1 Color 10 dark blue fast 40 41 28 29 15 9 Color 10 Color 11 fast 42 43 2A 2B 16 7 Color 11 cyan fast 44 45 2C 2D 1...

Page 16: ...128 191 80 BF 50 2 74 9 Gobo rotation fast slow CCW max 1 0 turns sec 192 253 C0 FD 75 3 99 2 Audio gobo chase slow each 4 th sound impulse new gobo 254 FE 99 6 6 Gobo Audio gobo chase fast each sound...

Page 17: ...0 02 03 02 03 1 0 1 180 04 05 04 05 1 7 1 270 06 07 06 07 2 5 PAN 2 0 08 09 08 09 3 3 2 90 10 11 0A 0B 4 1 2 180 12 13 0C 0D 4 9 2 270 14 15 0E 0F 5 7 PAN 3 0 16 17 11 11 6 5 3 90 18 19 12 13 7 3 3 18...

Page 18: ...o Phillips screws on the bottom side of the unit 3 Release carefully the lamp holder plate from the duct where the lamp is mounted on 4 Replace the old lamp Don t touch the glass bulb of the lamp with...

Page 19: ...light output but will also allow the fixture to function reliable throughout its life A soft lint free cloth moistened with any good glass cleaning fluid is recom mended under no circumstances should...

Page 20: ...eaners Change the lens if it looks milky about 1 2 years For that please contact your local dealer 7 3 Cleaning the Optical System 1 Pull out the main plug 2 Wait min 20 minutes after the last operati...

Page 21: ...rd objective Lens anti reflex Colors 11 dichroic filter plus white Gobos 10 rotating and positioning Gobos open Gobo outside diameter 25 mm image size 17 mm Gobo thickness stainless steel 0 15 mm Gobo...

Page 22: ...nnected load 6 D DIN VDE 0711 217 6 Display 12 DMX Address 8 DMX Input 11 DMX Start address 6 E Error Messages 13 EU model 6 F Fuses 6 G Glass Gobo 17 I Injury of the retina 5 Invert 9 L Lamp type 20...

Page 23: ...1 instruction version 0 91 GLP z German Light Production...

Reviews: