![Glowworm SAXONY 2 BBU FIRE FRONT Instructions For Use Installation And Servicing Download Page 28](http://html1.mh-extra.com/html/glowworm/saxony-2-bbu-fire-front/saxony-2-bbu-fire-front_instructions-for-use-installation-and-servicing_2234650028.webp)
Supplied By www.heating spares.co Tel. 0161 620 6677
28
221648B
Diagram 7.8
GAS TAP MOUNTING
BRACKET SECURING
SCREW
ELECTRICAL
CONNECTIONS
MICRO SWITCH
SECURING
SCREW (2)
INSULATION
MICRO
SWITCH
INSULATION
NUT (2)
GAS TAP
MOUNTING
BRACKET
3960 S
5248
Diagram 7.7
EARTH
POST
ELECTRODE
18
67
ELECTRODE
SPARK GAP
3
+ 1.0
- 0.5
EARTH
POST
ELECTRODE
TOP VIEW
EARTH
POST
C
L
7 Servicing