Supplementary Instructions
This appliance is fitted with a flue blockage safety device which
will shut down the appliance in the event of abnormal flue
conditions. This device is NOT a substitute for an independently
mounted Carbon Monoxide detector.
As this fire front may be fitted to a Glow-worm 45, 56, 45R or 56R
back boiler unit WITHOUT a flue blockage safety device, the
following instructions on how to light the boiler should be read
and followed in place of those in the main instructions for use.
To check if a flue blockage safety device is fitted, refer to the
inset in diagram 18, if one is fitted this supplement MUST be
ignored.
Lighting the Boiler
The boiler controls are placed behind the fire front plinth, see
diagram 3.
To remove the plinth, pull it gently forwards until it is free.
Refer to diagram 20 to identify the controls.
Turn off the electrical supply at the mains supply outside the
appliance.
Check that all controls are calling for heat.
The clock, room thermostat and programmer, if fitted, will be
away from the unit, see manufacturer’s instructions supplied
with them.
Turn the thermostat control knob “B” to “Off” position, that is,
fully anticlockwise, “Off” to be against the pointer.
Push in and slightly turn gas control knob “A” clockwise until
“
” is against its setting point, that is, set to “Off”.
Push in slightly and turn gas control knob “A” anticlockwise until
“
” is against its setting point, then push fully in and hold in.
At the same time press and release piezo button “D” until pilot
burner “E” lighted. Look at flame through viewing window “F”.
At initial lighting of the boiler air may be present and several
attempts may be needed to light the pilot. Keep control knob “A”
pushed in whilst operating the ignition button.
When the pilot is alight and stable, keep knob “A” fully pushed
in for about 15 seconds then release. Check that the pilot is still
alight, look through window “F”.
If the pilot burner fails to stay alight turn gas control knob “A”
“Off”, that is, fully clockwise. Wait three minutes. Repeat the
lighting operation, only now keep control knob “A” pushed in for
a little longer than before after the pilot has lit.
NOTE. Always wait three minutes before attempting to relight
the pilot after it has gone out for any reason.
Push control knob “A” in slightly and turn anticlockwise until
“
“ is against the setting point.
Note. If gas control knob “A” is turned until “
” is against the
setting point, a safety lock prevents it being turned on again. No
attempt should be made to turn the valve on again until at least
three minutes have elapsed.
Turn on the electrical supply to the unit.
Turn the boiler thermostat knob “B” clockwise until “MAX” is
against the setting point, the main burner will light.
Adjust the thermostat to the required setting between “MIN” and
“MAX”. “MAX” is about 82
o
C.
Check that all external controls are set to your requirements.
Refit the plinth by carefully locating the top edge of the plinth into
the sliders, then push gently back as far as it will go.
'E' PILOT BURNER
BOILER CONTROLS
Diagram 20
INSET: Showing a Flue Blockage
Safety Device fitted.
SETTING
POINT
'F' VIEWING
WINDOW
'D' PIEZO
UNIT
BUTTON
'B'
THERMOSTAT
CONTROL
KNOB
OFF
PILOT/IGNITION
MAIN BURNER
'A'
GAS VALVE
CONTROL
KNOB
SETTING
POINT