Supplied By www.heating spares.co Tel. 0161 620 6677
22
221648B
5 Lighting, Testing and Fitting Internal Parts
5.2 Internal Parts - Fitting
Caution. If any of the internal fire front parts are damaged DO
NOT light or further test the fire front until replacement parts are
fitted.
Refit gas tap control knob.
Swing the side panels out by about 5mm, to their stops.
Warning. The Glass panel can be hot.
Remove the glass panel, see diagram 3.3.
Fit the combustion chamber bottom plate, inside base tray, see
diagram 5.3.
Follow sequence in diagrams 9 to 16. (Instructions for Use). to
fit internal fire front parts.
Note. The fuel effect pieces are marked on their backs.
5.3 Decorative Castings
Fit the front legs as diagram 5.4, decorative side castings as
diagram 5.5, front casing as diagram 5.6, replace glass panel
assembly as diagram 3.3, and canopy as diagram 17.
(Instructions for Use). Take care as it is made of cast iron.
Note. The canopy is fitted with two adjusting screws, see
diagram 5.7. These should be adjusted so that the canopy
sides fit parallel to the side panels.
This adjustment can be done when the canopy is in place.
5.4 Fitting of Plinth
Before fitting the plinth please read the instructions on it.
Fit the plinth onto the guides and push it back as far as it will go,
see diagram 3. (Instructions for Use).
5.5 Heat Settings
Light the fire front burner as the relevant part of
Section 6.1.
Refer to diagram 5. (Instructions for Use).
At tap position 1 -
centre section flame effect.
At tap position 2 -
centre section flame effect with
outer sections fuel bed glow.
At tap position 3 -
centre and outer sections flame
effect with fuel bed glow.
At tap position 4 -
(full on) full flame effect and fuel
bed glow.
In the unlikely event of the flame going out when the fire front
burner is on, then turn off. Wait three minutes before relighting.
If relighting for any other reason, wait two minutes before doing
so.
5.6 Test for Clearance of Products
Notes
WARNING. Take care, the appliance will get hot during tests.
For the test you will need a smoke match, extension and a torch.
IN ALL CASES, if spillage continues after the specified test
periods steps must be taken to put the fault(s) right.
If the problem cannot be put right the appliance must be
disconnected and expert advice sought.