Glow-worm Xtramax HE Instructions For Use Manual Download Page 8

www.high-efficiency.info

8

Spare Parts

REMEMBER:

 When replacing a part on this boiler, use only 

spare parts that you can be assured conform to the safety 

and performance specification that we require. Do not use 

reconditioned  or  copy  parts  that  have  not  been  clearly 

authorised by Glow-worm.

If replacement parts are required contact Glow-worm’s own 

service organisation using the telephone number on the inside 

front cover of this booklet.

Please quote the name of the boiler, this infomation will be 

on the name badge on the front case.

If  in  doubt  seek  advice  from  the  local  gas  company  or           

Glow-worm’s own service organisation using the telephone 

number on the inside front cover of this booklet.

Servicing

To ensure the continued efficient and safe operation of the 

boiler it is recommended that it is checked and serviced at 

regular intervals. The frequency of servicing will depend upon 

the site conditions and usage, but in general, once a year 

should be enough.

If this boiler is installed in a rented property in the UK there 

is a duty of care imposed on the owner of the property by 

the  current  issue  of  the  Gas  Safety  (Installation  and  Use) 

Regulations, Section 35.

Servicing/maintenance should be carried out by a 

competent 

person

 inaccordance with the rules in force in the countries 

of destination.

To obtain service, please call your installer or Glow-worm’s 

own service organisation using the telephone number on the 

inside front cover of this booklet.

Cleaning

The boiler casing can be cleaned using a mild liquid detergent 

with a damp cloth, then a dry cloth to polish.

Do not use any form of abrasive or solvent cleaner as you 

may damage the paintwork.

Frost Protection

 

If the mains electricity and gas services are to be turned off for 

any long periods during severe weather, it is recommended 

that the whole system, including the  boiler, should be drained 

to avoid the risk of freezing.

Maintenance

Summary of Contents for Xtramax HE

Page 1: ...f ciency info 1 To b e l e f t w i t h t h e u s e r Instructions for Use 002000 A 05 05 Glow worm Nottingham Road Belper Derbyshire DE56 1JT www high ef ciency info High Ef ciency Condensing Boilers...

Page 2: ...her on or off Open all doors and windows ventilate the area SHEETMETAL PARTS This boiler contains metal parts components and care should be taken when handling and cleaning with particular regard to e...

Page 3: ...www high ef ciency info 3 Xtramax HE...

Page 4: ...9 User Controls Display page 10 CONTENTS The instructions are an integral part of the boiler and must to comply with the current issue of the Gas Safety Installation and Use Regulations be handed to t...

Page 5: ...gas but may be adjusted for use on G31 propane Testing and Certi cation This boiler certi cated to the current issue of EN 483 for perform ance and safety It is important that no alteration is made to...

Page 6: ...nsation from the ue terminal in cool weather This is due to the high ef ciency and hence low ue gas temperature of the boiler It is normal and not a fault indication Electrical Supply Failure Reset Sw...

Page 7: ...ystem pump when the temperature in the heating circuit falls below 40 C When the temperature inside the boiler rises to 70 C the burner will switch off and only the system pump will run at 100 C the p...

Page 8: ...ency of servicing will depend upon the site conditions and usage but in general once a year should be enough If this boiler is installed in a rented property in the UK there is a duty of care imposed...

Page 9: ...em Pressurisation The digital display see diagram 4 normally shows the operating temperature of the unit when there is a central heating demand and gives a pressure reading when there is no demand or...

Page 10: ...ol to 0 to switch off heating If the boiler fails to light reset the controls see paragraph below TO RESET If a fault occurs the running lamp will ash red and a fault code will appear on the digital d...

Page 11: ...ser Controls Display 9934 CONTROLS FASCIA MAINS RESET SWITCH DIGITAL DISPLAY CONTROL LIGHT HOT WATER TEMPERATURE CONTROL ECONOMY POSITION APPROX 55O MAXIMUM POSITION APPROX 62O CENTRAL HEATING WATER T...

Page 12: ...www high ef ciency info 12 www high ef ciency info Because of our constant endeavour for improvement details may vary slightly from those shown in these instructions...

Reviews: