Glow-worm Xtramax HE Instructions For Use Manual Download Page 5

www.high-efficiency.info

5

Gas Safety (Installation and Use) Regulations

In your own interests and that of safety, it is the Law  that ALL gas 
appliances are installed by a 

competent person

 in accordance 

with the current issue of the regulations.

Control of Substances Hazardous to Health

Under Section 6 of The Health and Safety at Work Act 1974, we 
are  required  to  provide  information  on  substances  hazardous  to 
health. 
The adhesives and sealants used in this appliance are cured and 
give no known hazard in this state.

Electrical Connection

The boiler 

MUST

 be earthed.

The  boiler 

MUST

be  connected  to  a  permanent  230V  ac,  50Hz 

supply.
Connection  of  the  whole  electrical  system  of  the  boiler,  including 
any heating controls, to the electrical supply must be through one 
common isolator and must be fused 3 Amp maximum.
The colours of three core flexible cable are, blue - neutral, brown 
- live, green and yellow - earth.

IMPORTANT NOTE

 

ALL electrical connections to the boiler 

must be permenantly  fixed to a wall or a 

sturdy support feature.

Gas Category

This boiler is for use on G20 natural gas, but may be adjusted for 
use on G31 propane.

Testing and Certification

This boiler certificated to the current issue of EN 483 for perform-
ance and safety. 
It is important that no alteration is made to the boiler unless ap-
proved, in writing, by Glow-worm.
Any  alteration  not  approved  by  Glow-worm,  could  invalidate  the 
certification, boiler warranty and may also infringe the current issue 
of the statutory requirements.

CE Mark

This boiler meets the requirements of Statutory Instrument, No. 3083 
The Boiler (Efficiency) Regulations, and therefore is deemed to meet 
the requirements of Directive 92/42/EEC on the efficiency requirements 
for new hot water boilers fired with liquid or gaseous fuels.
Type  test  for  purposes  of  Regulation  5  certified  by:  Notified  body 
0087.
Product/production certified by: Notified body 0086.
The CE mark on this appliance shows compliance with:
1.   Directive 90/396/EEC on the approximation of the laws of the 
Member States relating to appliances burning gaseous fuels.
2.   Directive 73/23/EEC on the harmonisation of the Laws of the 
Member  States  relating  to  electrical  equipment  designed  for  use 
within certain voltage limits.
3.   Directive 89/336/EEC on the approximation of the Laws of the 
Member States relating to electromagnetic compatibility.

Important Information

Summary of Contents for Xtramax HE

Page 1: ...f ciency info 1 To b e l e f t w i t h t h e u s e r Instructions for Use 002000 A 05 05 Glow worm Nottingham Road Belper Derbyshire DE56 1JT www high ef ciency info High Ef ciency Condensing Boilers...

Page 2: ...her on or off Open all doors and windows ventilate the area SHEETMETAL PARTS This boiler contains metal parts components and care should be taken when handling and cleaning with particular regard to e...

Page 3: ...www high ef ciency info 3 Xtramax HE...

Page 4: ...9 User Controls Display page 10 CONTENTS The instructions are an integral part of the boiler and must to comply with the current issue of the Gas Safety Installation and Use Regulations be handed to t...

Page 5: ...gas but may be adjusted for use on G31 propane Testing and Certi cation This boiler certi cated to the current issue of EN 483 for perform ance and safety It is important that no alteration is made to...

Page 6: ...nsation from the ue terminal in cool weather This is due to the high ef ciency and hence low ue gas temperature of the boiler It is normal and not a fault indication Electrical Supply Failure Reset Sw...

Page 7: ...ystem pump when the temperature in the heating circuit falls below 40 C When the temperature inside the boiler rises to 70 C the burner will switch off and only the system pump will run at 100 C the p...

Page 8: ...ency of servicing will depend upon the site conditions and usage but in general once a year should be enough If this boiler is installed in a rented property in the UK there is a duty of care imposed...

Page 9: ...em Pressurisation The digital display see diagram 4 normally shows the operating temperature of the unit when there is a central heating demand and gives a pressure reading when there is no demand or...

Page 10: ...ol to 0 to switch off heating If the boiler fails to light reset the controls see paragraph below TO RESET If a fault occurs the running lamp will ash red and a fault code will appear on the digital d...

Page 11: ...ser Controls Display 9934 CONTROLS FASCIA MAINS RESET SWITCH DIGITAL DISPLAY CONTROL LIGHT HOT WATER TEMPERATURE CONTROL ECONOMY POSITION APPROX 55O MAXIMUM POSITION APPROX 62O CENTRAL HEATING WATER T...

Page 12: ...www high ef ciency info 12 www high ef ciency info Because of our constant endeavour for improvement details may vary slightly from those shown in these instructions...

Reviews: