Glow-worm Xtramax HE Instructions For Use Manual Download Page 6

www.high-efficiency.info

6

Boiler Design

Description  

Xtramax HE Model:

 The boiler is designed to provide central 

heating and instantaneous hot water.

Once the controls are set the boiler operates automatically.

Compartment or Cupboard Installations

Ventilation  is  not  required  for  compartment  or  cupboard 

installations.

Do not use the compartment or cupboard for storage.

The minimum clearances to fixtures are shown in  

diagram 1.

Pluming from flue terminal

Like  all  condensing  boilers  it  will  produce  a  plume  of 

condensation from the flue terminal in cool weather.  This is 

due to the high efficiency and hence low flue gas temperature 

of the boiler.  It is normal and not a fault indication.

Electrical Supply Failure Reset Switch

The boiler will not work without an electrical supply.

Normal  operation  of  the  boiler  should  resume  when  the 

electrical supply is restored. 

Reset any external controls, to resume normal operation of 

the central heating.

If the boiler does not resume normal operation turn the mains 

reset switch off and on.  If the boiler does not resume normal 

operation after this the overheat stat may have operated.  

+ A removable compartment door can be placed 

at least 5mm in front of the appliance

5

5

600 +

200

50

Diagram 1

Summary of Contents for Xtramax HE

Page 1: ...f ciency info 1 To b e l e f t w i t h t h e u s e r Instructions for Use 002000 A 05 05 Glow worm Nottingham Road Belper Derbyshire DE56 1JT www high ef ciency info High Ef ciency Condensing Boilers...

Page 2: ...her on or off Open all doors and windows ventilate the area SHEETMETAL PARTS This boiler contains metal parts components and care should be taken when handling and cleaning with particular regard to e...

Page 3: ...www high ef ciency info 3 Xtramax HE...

Page 4: ...9 User Controls Display page 10 CONTENTS The instructions are an integral part of the boiler and must to comply with the current issue of the Gas Safety Installation and Use Regulations be handed to t...

Page 5: ...gas but may be adjusted for use on G31 propane Testing and Certi cation This boiler certi cated to the current issue of EN 483 for perform ance and safety It is important that no alteration is made to...

Page 6: ...nsation from the ue terminal in cool weather This is due to the high ef ciency and hence low ue gas temperature of the boiler It is normal and not a fault indication Electrical Supply Failure Reset Sw...

Page 7: ...ystem pump when the temperature in the heating circuit falls below 40 C When the temperature inside the boiler rises to 70 C the burner will switch off and only the system pump will run at 100 C the p...

Page 8: ...ency of servicing will depend upon the site conditions and usage but in general once a year should be enough If this boiler is installed in a rented property in the UK there is a duty of care imposed...

Page 9: ...em Pressurisation The digital display see diagram 4 normally shows the operating temperature of the unit when there is a central heating demand and gives a pressure reading when there is no demand or...

Page 10: ...ol to 0 to switch off heating If the boiler fails to light reset the controls see paragraph below TO RESET If a fault occurs the running lamp will ash red and a fault code will appear on the digital d...

Page 11: ...ser Controls Display 9934 CONTROLS FASCIA MAINS RESET SWITCH DIGITAL DISPLAY CONTROL LIGHT HOT WATER TEMPERATURE CONTROL ECONOMY POSITION APPROX 55O MAXIMUM POSITION APPROX 62O CENTRAL HEATING WATER T...

Page 12: ...www high ef ciency info 12 www high ef ciency info Because of our constant endeavour for improvement details may vary slightly from those shown in these instructions...

Reviews: