Glow-worm Ultimate 3 30c Operating Instructions Manual Download Page 9

Operation 4

0020239565_01

 

Ultimate

 

3

 

Operating

 

instructions

9

3.

Timer

You can control the heating mode using 

the timer.

Position for
the selection
switch

Functionality

0

Heating mode permanently

switched off
Heating mode intervals in

accordance with the timer

I

Heating mode permanently

switched on

Set the timer. (

Page 11)

3.

Operating

 

levels

The product has two operating levels:

The operator level shows the most im-

portant information and offers set-up

options which do not require any special

prior knowledge.

Specialised knowledge is required in or-

der to use the installer level (access for

competent persons). This is therefore

protected by an access code.

Operator level

overview (

Page 15)

4 Operation

4.1 Starting up the product
4.1.1 Opening the isolator devices

Conditions

: The competent person who installed

the unit will explain where the isolator devices are

and how to handle them.

Ensure that the gas isolator cock is fully

open.

Ensure that the stop cocks in the heat-

ing installation's flow and return are

open.

Ensure that the cold water stop cock is

open.

4.1.2 Starting up the product

1

2

Press the

(2)

button.

When the unit is switched on, the

"Basic display" is shown in the

display

(1)

.

4.2 Basic display

The filling pressure in the heating installa-

tion and the operating mode are shown in

the display's basic display.
To return to the basic display:

Wait more than five seconds without

pressing any buttons.

If a fault message is present, the basic

display switches to the fault code.

4.3 Checking the heating system

pressure

1. Once a month, check that the pressure

in the central heating system, which

is displayed on the user interface,

is between 0.1 MPa and 0.15 MPa

(1.0 bar and 1.5 bar).

If the filling pressure is correct, no

action needs to be taken.

If the filling pressure is too low, add

more water to the heating installa-

tion.

Summary of Contents for Ultimate 3 30c

Page 1: ...The energy you need Operating instruc tions Ultimate 3 30c 35c GB IE...

Page 2: ...the heating system pressure 9 4 4 Filling the heating installation 10 4 5 Selecting the operating mode 10 4 6 Setting the hot water temperature 10 4 7 Setting the heating flow temperature 11 4 8 Produ...

Page 3: ...l heating installations and for hot water generation Intended use includes the fol lowing observance of the operating instructions included for the product and any other system components compliance w...

Page 4: ...windows fully and ensure adequate ventilation Do not use naked flames e g lighters matches Do not smoke Do not use any electrical switches mains plugs door bells telephones or other communication syst...

Page 5: ...e bridge or block the safety devices Do not tamper with any of the safety devices Do not damage or remove any seals on components Do not make any changes The product itself to the gas air water and el...

Page 6: ...all rooms are sufficiently heated If you cannot ensure the op eration have a competent person drain the heating in stallation 2 Notes on the documentation 2 1 Observing other applicable documents You...

Page 7: ...bar x kPa Gas group and gas connec tion pressure as set at the factory Cat Approved gas category Condensing technology Efficiency of the boiler in accordance with directive 92 42 EWG 3 2 Benchmark Glo...

Page 8: ...button 4 button 5 button 3 6 Description of the display 1 2 3 1 Operating in formation 2 Active operating mode selecting and confirming the operating mode 3 Display showing the current heat ing flow...

Page 9: ...unit will explain where the isolator devices are and how to handle them Ensure that the gas isolator cock is fully open Ensure that the stop cocks in the heat ing installation s flow and return are o...

Page 10: ...a tion the first time any subsequent top ups and the water quality The operator alone is respons ible for topping up the water in the heating installation 1 Open all radiator valves thermostatic radia...

Page 11: ...The actual heating flow temperature is set automatically by the controller Conditions Outside temperature sensor connected to the boiler with heating mode activated When you press the or but ton The...

Page 12: ...The hot water circuit cold and hot water is not protected by the boiler Frost protection for the system can only be guaranteed by the boiler A controller is required to control the tem perature of th...

Page 13: ...or faults and particularly for blockages You must not be able to see or feel any obstructions in the condensate drain pipe work and tundish If you notice a fault have it rectified by a competent perso...

Page 14: ...ce 9 1 Guarantee For information on the manufacturer s guarantee you can write to the contact address that is provided on the back page 9 2 Customer service For contact details for our customer ser vi...

Page 15: ...Open the cold water stop cock The power supply in the building is dis connected Check the fuse in the build ing The product automatically switches on after the power supply is restored The product is...

Page 16: ...on After three successive failed ignition attempts the system switches to fault mode fault code F 28 Press the button The product carries out a new ignition attempt If the ignition problem is not rec...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...nical helpline 0330 100 7679 After sales service 0330 100 3142 www glow worm co uk 0020239565_01 15 07 2019 supplier These instructions or parts thereof are protected by copyright and may be reproduce...

Reviews: