3 Product description

8

Information
on the identi-
fication plate

Meaning

Type: Xx3(x)

Approved flue gas connec-

tions

PMS

Maximum water pressure in

heating mode

PMW

Maximum water pressure in

hot water handling mode

V/Hz

Electric connection

W

Max. electrical power con-

sumption

IP

Level of protection
Heating mode
Hot water generation

P

n

Nominal heat output range

in heating mode

P

nc

Nominal heat output range

in heating mode (condensing

technology)

P

Nominal heat output range

in hot water handling mode

Q

n

Nominal heating load range

in heating mode

Q

nw

Nominal heating load range

in hot water handling mode

T

max.

Max. flow temperature

NOx

NOx class for the product

Code (DSN)

Specific product code

GC no.

Gas council number

3.

5

 

Overview

 

of

 

the

 

operator

control elements

1

2

3

4

5

1

Display

2

button

3

button

4

button

5

button

3.

6

 

Description

 

of

 

the

 

display

1

2

3

1

Operating in-

formation

2

Active operating

mode, selecting

and confirming

the operating

mode

3

Display showing

the current heat-

ing flow temper-

ature, the filling

pressure in the

heating install-

ation, the oper-

ating mode or a

fault code

3.

7

 

Description

 

of

 

button

functions

Button

Meaning

Selecting the operating mode

Confirm the operating mode

Confirm setting

Increase the display contrast

or

Setting the hot water temperat-

ure

Setting the heating flow tem-

perature

Increase or decrease the selec-

ted setting

Increase the display contrast

Activate the product: On/off

(standby)

Reset the product

Adjustable

 

values

 

flash

 

on

 

the

 

display.

You

 

must

 

confirm

 

any

 

change

 

to

 

a

 

value.

 

Only

 

then

 

is

 

the

 

new

 

setting

 

saved.

If

 

you

 

do

 

not

 

press

 

any

 

buttons

 

for

 

five

 

seconds,

 

the

 

displays

 

switches

 

back

 

to

 

the

 

basic

 

display.

If

 

you

 

do

 

not

 

press

 

any

 

buttons

 

for

 

one

 

minute,

 

the

 

display

 

contrast

 

decreases.

Operating

 

instructions

 

Ultimate

 

3

 

0020239565_0

1

Summary of Contents for Ultimate 3 30c

Page 1: ...The energy you need Operating instruc tions Ultimate 3 30c 35c GB IE...

Page 2: ...the heating system pressure 9 4 4 Filling the heating installation 10 4 5 Selecting the operating mode 10 4 6 Setting the hot water temperature 10 4 7 Setting the heating flow temperature 11 4 8 Produ...

Page 3: ...l heating installations and for hot water generation Intended use includes the fol lowing observance of the operating instructions included for the product and any other system components compliance w...

Page 4: ...windows fully and ensure adequate ventilation Do not use naked flames e g lighters matches Do not smoke Do not use any electrical switches mains plugs door bells telephones or other communication syst...

Page 5: ...e bridge or block the safety devices Do not tamper with any of the safety devices Do not damage or remove any seals on components Do not make any changes The product itself to the gas air water and el...

Page 6: ...all rooms are sufficiently heated If you cannot ensure the op eration have a competent person drain the heating in stallation 2 Notes on the documentation 2 1 Observing other applicable documents You...

Page 7: ...bar x kPa Gas group and gas connec tion pressure as set at the factory Cat Approved gas category Condensing technology Efficiency of the boiler in accordance with directive 92 42 EWG 3 2 Benchmark Glo...

Page 8: ...button 4 button 5 button 3 6 Description of the display 1 2 3 1 Operating in formation 2 Active operating mode selecting and confirming the operating mode 3 Display showing the current heat ing flow...

Page 9: ...unit will explain where the isolator devices are and how to handle them Ensure that the gas isolator cock is fully open Ensure that the stop cocks in the heat ing installation s flow and return are o...

Page 10: ...a tion the first time any subsequent top ups and the water quality The operator alone is respons ible for topping up the water in the heating installation 1 Open all radiator valves thermostatic radia...

Page 11: ...The actual heating flow temperature is set automatically by the controller Conditions Outside temperature sensor connected to the boiler with heating mode activated When you press the or but ton The...

Page 12: ...The hot water circuit cold and hot water is not protected by the boiler Frost protection for the system can only be guaranteed by the boiler A controller is required to control the tem perature of th...

Page 13: ...or faults and particularly for blockages You must not be able to see or feel any obstructions in the condensate drain pipe work and tundish If you notice a fault have it rectified by a competent perso...

Page 14: ...ce 9 1 Guarantee For information on the manufacturer s guarantee you can write to the contact address that is provided on the back page 9 2 Customer service For contact details for our customer ser vi...

Page 15: ...Open the cold water stop cock The power supply in the building is dis connected Check the fuse in the build ing The product automatically switches on after the power supply is restored The product is...

Page 16: ...on After three successive failed ignition attempts the system switches to fault mode fault code F 28 Press the button The product carries out a new ignition attempt If the ignition problem is not rec...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...nical helpline 0330 100 7679 After sales service 0330 100 3142 www glow worm co uk 0020239565_01 15 07 2019 supplier These instructions or parts thereof are protected by copyright and may be reproduce...