Product description 2
0020288229_00
MiSet
Operating and installation instructions
13
MENU
→
SETTINGS
→
Installer level
→
Installation configuration
→
Cylinder charging
offset: K
Desired tempe offset = flow temperature for the domestic
hot water cylinder.
→
Max. cyl. charging
time:
Setting the maximum time at which the domestic hot water cylin-
der can be charged without interruption. If the maximum time or
the target temperature is reached, the system control enables the
heating function. The setting
Off
means that the cylinder char-
ging time is not restricted.
→
Cyl. charg. anti-cycl.
time: min
Setting the time period during which the cylinder charging is
blocked after the maximum cylinder charging time has elapsed.
During the blocked time, the system control enables the heating
function.
→
Parallel cylinder char-
ging:
When charging the domestic hot water cylinder, the mixing cir-
cuit is heated in parallel. The non-mixed heating circuit is always
switched off during cylinder charging.
→
Screed drying profile
Setting target flow temperature per day in accordance with the
construction regulations