0020008566A

FLUE ELBOW

COMBUSTION
ANALYSER
TEST POINT

FLUE DUCT
EXTENSION

Important Notes

To ensure the continued efficient and safe operation of the
boiler it is recommended that it is checked and serviced at
regular intervals.  The frequency of servicing will depend upon
the particular installation and usage, but in general once a year
should be enough.

It is the Law that any servicing is carried out by a 

competent

person

.

When replacing a part on this appliance, use only spare parts
that you can be assured conform to the safety and performance
specification that we require.  Do not use reconditioned or copy
parts that have not been clearly authorised by Glow-worm.

5.1 General

Measurement of the products of combustion can be achieved
by connection of a probe to the combustion analyser test point,
see diagram 5.1.

IMPORTANT NOTE:

   Products of combustion will be discharged

when the cap is removed. It is important to replace the cap
immediately..

Testing Flue Gases:

  If any doubt exists that the flue products

are not exhausting correctly, investigate by use of a gas
analyser (FGA).

Diagram 5.1

12853

5  Servicing

Because of our constant endeavour for improvement, details may vary slightly from those shown in these instructions.

Summary of Contents for cxi

Page 1: ...r to diagram 1 If you have been supplied with Standard horizontal flue pack Pt No 2000460360 or Pt No A2037300 you will find the instructions for the preparation and installation of these flues within...

Page 2: ...om inside the building when access to the outside wall face is not practicable The diagrams 2 1 to 2 4 describe the lengths achievable without the use of extensions or elbows TOP SIDE FLUE TELESCOPIC...

Page 3: ...5 These dimensions comply with the building regulations but they may need to be increased to avoid wall staining and nuisance from pluming depending on site conditions Plume Management Kit can be use...

Page 4: ...rom the boiler Where this line reaches the side wall a horizontal line should be marked The vertical centre line of the flue should then be marked at 176mm from the back wall see diagram 3 2 To allow...

Page 5: ...al flue accessories are available to suit your site conditions see diagram 4 1 The Glow worm Flue Options Guide available on request or through the web site describes in detail the necessary accessori...

Page 6: ...he flue it can project to a maximum of 600mm if this is not desirable then a Standard flue MUST be used and cut to length Top Rear flue Standard with the flue elbow temporarily fitted measure the dist...

Page 7: ...hrough two of the pre drilled holes in the collar Remove collar and drill two 3mm diameter holes in the elbow take care not to pierce the inner flue duct Insert the terminal flue duct remembering to e...

Page 8: ...ed conform to the safety and performance specification that we require Do not use reconditioned or copy parts that have not been clearly authorised by Glow worm 5 1 General Measurement of the products...

Reviews: