3  Installation Preparation

3.1 Wall Template

Take the wall template from the fixing jig pack and place in the
desired position on a flat wall, giving due consideration to boiler
clearances, see section 2, and the flue you are fitting.

IMPORTANT-

  If the template refers to type 'A' and 'B' flues,

please use only type 'B' references.

3.2 Flue Hole Cutting

The 

standard horizontal flue 

is designed with an internal fall

of 35mm/metre towards the boiler for disposal of condensate.
If the standard flue length alone is being used then the flue hole
of diameter 105mm can be cut in the position marked on the wall
template.

For 

standard side flues 

the horizontal flue centre line on the

wall template should be extended to the side wall, and the
vertical centre of the flue hole marked at 176mm from the back
wall.

For installations with external access, a 105mm diameter core
drill can be used.

For installations with internal access only a 125mm diameter
core drill should be used.

When using extension pipes with the horizontal rear flue, a core
drill size of 125mm should be used to allow the extension pieces
to slope at 35mm/metre (2.5

°

) towards the boiler.

For 

extended side flues

, the flue hole centre should be

determined by extending the dashed inclined line on the template
to the side wall. This dashed line is drawn at 35mm/metre (2.5

o

)

rise from the boiler. Where this line reaches the side wall, a
horizontal line should be marked.  The vertical centre line of the
flue should then be marked at 176mm from the back wall, see
diagram 3.2.

To allow for the flue passing through the wall at this angle a
125mm hole should be drilled irrespective of internal or external
installation.

Remove the wall template whilst drilling the flue hole.

3.4 Fixing Jig and Hanging Bracket

Reposition the wall template over the flue hole and mark the
position of the fixing holes for the jig and the hanging bracket,
see diagram 3.3.

Drill the four fixing holes, 2 for the hanging bracket and 1 each
for the top hole of the fixing jig wall brackets and insert suitable
wall plugs.

If gas and/or water pipes are to be connected through the rear
wall, the holes must be drilled as marked on the wall template
prior to securing the fixing jig.

Secure the fixing jig wall brackets to the wall using suitable
screws.

NOTE:

 Due to the varied site conditions we do not supply fixings

and advise that the installer should supply those which are
suitable.

Locate the jig plate between the wall brackets and secure with
the No. 8 self tapping fixing screws supplied in the fittings pack.

130

130

191

16

Ø105

Ø125

2.5

°

2.5

°

127

2.5

°

2.5

°

Diagram 3.2

12075

WALL
TEMPLATE

EXTENDED SIDE FLUE

Ø 125

90

°

176

2.5

°

 Inclined

Extended flue length

Standard
flue length
Horizontal

HANGING
BRACKET

SCREW
(2 OFF)

SCREW

Diagram 3.3

12049

WALL PLUG

SCREW

WALL
TEMPLATE

FIXING JIG
PLATE

FIXING JIG
WALL BRACKETS
(2 OFF)
(Handed as shown)

WALL
PLUG

Summary of Contents for cxi

Page 1: ...r to diagram 1 If you have been supplied with Standard horizontal flue pack Pt No 2000460360 or Pt No A2037300 you will find the instructions for the preparation and installation of these flues within...

Page 2: ...om inside the building when access to the outside wall face is not practicable The diagrams 2 1 to 2 4 describe the lengths achievable without the use of extensions or elbows TOP SIDE FLUE TELESCOPIC...

Page 3: ...5 These dimensions comply with the building regulations but they may need to be increased to avoid wall staining and nuisance from pluming depending on site conditions Plume Management Kit can be use...

Page 4: ...rom the boiler Where this line reaches the side wall a horizontal line should be marked The vertical centre line of the flue should then be marked at 176mm from the back wall see diagram 3 2 To allow...

Page 5: ...al flue accessories are available to suit your site conditions see diagram 4 1 The Glow worm Flue Options Guide available on request or through the web site describes in detail the necessary accessori...

Page 6: ...he flue it can project to a maximum of 600mm if this is not desirable then a Standard flue MUST be used and cut to length Top Rear flue Standard with the flue elbow temporarily fitted measure the dist...

Page 7: ...hrough two of the pre drilled holes in the collar Remove collar and drill two 3mm diameter holes in the elbow take care not to pierce the inner flue duct Insert the terminal flue duct remembering to e...

Page 8: ...ed conform to the safety and performance specification that we require Do not use reconditioned or copy parts that have not been clearly authorised by Glow worm 5 1 General Measurement of the products...

Reviews: