17
2000225000B
10 Flue Installation Telescopic and Standard
Pho 087
Pho 451
B
C
J
I
H
F
G
A
D
The flue kit 86285 is 1000 mm long and comprises:
- Air duct pipe ..........................................................
A
- Flue duct pipe ........................................................
B
- Flue elbow ..............................................................
C
- Fixing collar .............................................................
D
- Locking clips ............................................................
E
- External rubber sealing collar ...............................
F
- Internal flange .......................................................
G
- Gasket .....................................................................
H
- Screws .......................................................................
I
- 'O' rings .....................................................................
J
Diagram 10.4
E
Diagram 10.5
10024
The flue kit A2004500 is 659.5 mm long and comprises:
- Telescopic flue assembly .....................................
A
- External rubber sealing collar ...............................
B
- Gasket .....................................................................
C
- Screws .....................................................................
D
- 'O' ring ......................................................................
E
Diagram 10.3
Telescopic flue kit
A
C
B
E
D
10.5 Installation of telescopic flue assembly
• The elbow must be removed from the air and flue duct pipes.
• Extend the telescopic flue assembly approximately 10 cm, If
the telescopic flue is pulled apart care must be taken not to
damage the ‘O’ ring on the flue duct when re-assembling.
• Remove the 2 securing screws on either side of the air elbow
end of the air duct pipe, carefully pull the air duct pipe off the air
elbow taking care not to disconnect the telescopic flue duct
pipes.
• Remove the 2 securing screws on either side of the flue elbow
to release the flue duct pipe, pull the flue duct pipe out of the flue
elbow, note the ‘O’ ring inside the flue elbow.
• Fit rubber sealing collar
(B), see diagram 10.3,
into groove at
the outer end of the air duct pipe
(A).
• Fit air/flue duct pipe assembly
(A)
into wall from the outside
with rubber sealing collar to the outside.
• Pull pipe assembly inwards to bring rubber sealing collar hard
up against external wall,
see diagram 10.5.
• Fit ‘O’ ring
(E)
into the underside of the flue elbow. Apply a
small amount of silicone grease to the ‘O’ ring when fitting.
• Remove the backing from the self adhesive gasket
(C)
and
carefully fit gasket to base of flue elbow.
• Leave the restrictor
(a)
fitted inside the fan outlet,
see diagram 10.6.
• Ensure transit plate has been removed from the fan outlet, on
top of the boiler.
• Fit elbow onto boiler and secure with the four screws
(D).
• Re-fit the telescopic flue duct pipe to the flue elbow taking care
not to tear the ‘O’ ring, fit the 2 securing screws.
• Re-fit the telescopic air duct pipe to the air elbow, fit the 2
securing screws.
10.6 Installation of standard flue assembly
• Ensure transit plate has been removed from the fan outlet, on
top of the boiler.
• Fit rubber sealing collar
(F), see diagram 10.4,
into groove at
the outer end of pipe
(A).
• Fit air duct pipe
(A)
into wall with groove to the outside.
• Pull pipe inwards to bring rubber sealing collar hard up against
external wall, see
diagram 10.5.
• Fit internal plastic flange
(G)
onto air duct pipe. Push along the
pipe until engaged against internal wall.
• From inside, insert flue duct pipe
(B)
into air duct pipe.
• Fit both ‘O’ rings
(J)
into the flue elbow
(C),
one at the inlet, one
at the outlet. By necessity, they are a loose fit, apply a small
amount of silicone grease to each ‘O’ ring when fitting.
• Fixing collar
(D)
over air duct pipe
(A)
and elbow
(C)
ensuring
it is the correct way round (Note: the fixing collar can only be
fitted one way due to the different diameters of the flue elbow
and air duct.
• Take hold of the flue duct pipe and push gently onto the elbow
outlet taking care not to tear the ‘O’ ring.
• Open fixing collar (
D
) and locate between elbow and air duct
pipe (
A
). Close fixing jig.
• Engage the two fixing clips
(E)
onto the collar
(D)
and press
down to lock into position. Secure clips with screws provided.
Important
: If the flue has been cut, ensure that there are no
burrs that could damage the ‘O’ ring.
Standard flue kit
• For flue systems less than 1,5 m long, fit the restrictor
(a)
in
the fan outlet, see
diagram 10.7.
• Remove the backing from the self adhesive gasket
(H)
and
carefully fit gasket to base of flue elbow.
• Fit elbow onto boiler and secure with the four screws
(I).