46
Glomar AG
l
Seestrasse 11
l
CH-9326 Horn
l
T +41 71 841 70 70
l
www.glomar.ch
46
STILO 60
english
16.1 Error codes Service
Failure
Cause / trouble shooting
after crimping process
green light
Operating data OK
green/red flashing
Operating data OK and service interval exceeded / service
needed
red flashing
Operating data marginal / please contact service center
red light
Operating data false / service needed
orange light
Temperature failure / tool has to be heated up or cooled
down
after inserting the battery
green light
No failure
orange light
Temperature failure / tool has to be heated up or cooled
down
The failure reports can be downloaded by using the Analysis Software. Please send the
data file with failure status to our service center.
16.2 Error codes Battery
Failure
Cause / trouble shooting
after crimping process
off
No malfunction
red flashing
Charge/change battery (approx. 10% capacity)
red light
Battery flat
after inserting the battery
green light
No malfunction
red light
Charge/change battery