ELECTROSTIMULATORS
Genesy 500
USER MANUAL
Rev
. 03_09.04
0476
Page 1: ...ELECTROSTIMULATORS Genesy 500 USER MANUAL Rev 03_09 04 0476...
Page 2: ...33 www globusitalia com info globusitalia com This product has been manufactured according to the technical regulations in force and is certified according to Directive 93 42 EEC for medical devices b...
Page 3: ...Executed AUTO STIM Automatic Favorites 2 2 Mode simultaneous stimulation 15 PROGRAMMING MENU 16 Create a new program Modify an existing program Eliminate a program ADVANCED MENU 17 INTENSITY OF STIMU...
Page 4: ...IST INCONTINENCE 25 DIAGNOSTICS 25 Rheobase calculation Chronaxie calculation Slope calculation PROGRAMS LIST DENERVATED 26 ELECTRODE PLACEMENT 27 WARRANTY TERMS 35 FREQUENTLY ASKED QUESTIONS 35 REV 0...
Page 5: ...resent If any material is missing please contact your retailer immedia tely Please also check the integrity of the stimulator and the supplied electrodes and cables Electrodes The supplied electrodes...
Page 6: ...bus Electrostimulator be used with caution in persons with capil lary fragility to avoid excessive capillary damage Potential adverse effects Skin irritation may occur in persons with particularly sen...
Page 7: ...vital functions Store in the supplied carrying case in conditions of 20 85 relative humidity and 5 45 C Recommendations for maintenance and use of electrodes and cables Clean and dry the skin prior t...
Page 8: ...r the following purposes Pain treatment in general Any type of sequential electrostimulation Aesthetic care Sports training The Electrostimulator may be used with or without the supervision of physici...
Page 9: ...ates To charge the batteries turn off the electrostimulator and detach the electrodes Attach the supplied battery charger by inserting the plug in the appropriate inlet on the electrostimulator figure...
Page 10: ...lored cables for EMS and TENS programs Use channels 1 and 3 with the gray cables for the Microcurrents MCR program Use channels 1 and 3 with the colo red cables for the Denervated Muscles program with...
Page 11: ...s selection 3 during a program Return to the previous phase DOWN DEL Move the selection down During a program simultaneously decrease the intensity of the 4 chan nels TIME During a program displays th...
Page 12: ...ried out before the message EMPTY appears proceed to the Program List Program selection from the Program List menu Use the UP and DOWN keys to position the cursor on Program List and confirm by press...
Page 13: ...m press OK Resumption after a pause repeats the last interrupted cycle Stop a program If you need to stop a program before its end switch off the instrument by pressing the OK key for 3 seconds Visual...
Page 14: ...y execution Registration in memory occurs automatically at the end of any program when the memory is full older programs are automatically deleted To recall a program in memory position the cursor on...
Page 15: ...ect the program for channels 3 and 4 Use the UP and DOWN keys to select the area of the second program channels 3 and 4 and confirm with OK 6 Use the UP and DOWN keys to select Man or Woman for the se...
Page 16: ...s display The following parameters are set sequentially Step 1 Type of stimulation After inserting the name of the new program use the UP and DOWN keys to select the desired type of stimulation by cho...
Page 17: ...up area and allows the duration of back lighting in stand by mode to be varied using the Up and Down keys Contrast FUNCTION The Contrast function present inside the Set up menu allows the level of co...
Page 18: ...uscle is contracted maximally This is intense treatment that should be performed only only after having carried out various applications at lower intensity In the descriptions of the various treatment...
Page 19: ...program may offer more than one difficulty level or body area to exercise PROGRAMS LIST PAIN ANTALGIC Endorphinic Tens Contracture Sciatica Lumbago Cervical pain Periathritis S O Epicondylitis Carpal...
Page 20: ...rou tes of the pain Against every kind of pain It can be used every time you need to relieve pain Warning TENS pro grammes relieve pain but do not eli minate its cause If it persists see the doc tor O...
Page 21: ...timulator automatically brings the intensity to the correct level This value should not be altered during execution of the program The Microcurrents programs cannot be run in the 2 2 mode with other t...
Page 22: ...t with metallic items e g tables and chairs Use of iontophoresis programs The duration of iontophoresis programs is automatically set for 10 min Once the program has started it is possible to modify t...
Page 23: ...equelae of fractu res myalgia osteoarthrosis Thiomucase Lumbago cervical pain cellulitis Sodium Chloride Sclerotic and softener Use with low intensity current Calcium Chloride Increase cal cium conten...
Page 24: ...aproxen Dioxilase Orudis ketoprofen Dicloreum diclofenac Tantum benzydamine Dievril Xylocaine lidocaine Essaven gel Fastum gel ketoprofen Flectadol lysine acetylsalicylate Fibrase pentosan polysulfate...
Page 25: ...des it relates to the contractile value of the muscle and to its trophism Chronaxie calculation The instrument automatically selects a value of intensity twice that of the rheobase The ampli tude of t...
Page 26: ...of the impulse and duration of the rest period Triangular currents These currents reach a maximal value of intensity with a linear ramp that combined with impul ses of rather long duration causes a c...
Page 27: ...OF ARM BICEPS BRACHII 2 TRICEPS MUSCLE OF ARM TRICEPS BRACHII 3 WRIST AND FINGER EXTENSORS 5 DELTOID MUSCLE 4 WRIST AND FINGER FLEXORS 6 DELTOID MUSCLES ANTERIOR Work position Work position Work posit...
Page 28: ...STERIOR 8 GREATER AND SMALLER PECTORAL MUSCLES 9 BREAST 12 10 MUSCULUS LATISSIMUS DORSI 11 TRAPEZIUS MUSCLE Work position Work position Work position Work position Work position Work position MUSCULUS...
Page 29: ...ition Work position Work position Work position Work position Work position MUSCULUS RECTUS ABDOMINIS MUSCULUS LATISSIMUS DORSI AND MUSCULUS ILEOCOSTAL THORACIS MUSCULUS RECTUS ABDOMINIS AND EXTER NAL...
Page 30: ...EMENT 22 FACE TRAPEZIUS MUSCLES CERVICAL VERTE BRAE 24 PERIARTHRITIS OF SCAPEL OR HUMERUS 21 GLUTEUS MUSCLES 19 QUADRICEPS 20 INTERNAL THIGH Work position Work position Work position Work position Wor...
Page 31: ...3 09 04 ELECTRODE PLACEMENT 26 EPICONDYLITIS 25 EPICONDYLITIS 27 CERVICOBRACHIAL NEURALGIA 28 BACK 29 SCIATICA 30 KNEE Work position Work position Work position Work position Work position Work positi...
Page 32: ...REV 03 09 04 32 Work position Work position Work position Work position Work position Work position 31 32 33 34 35 36 ELECTRODE PLACEMENT for microcurrents...
Page 33: ...REV 03 09 04 ELECTRODE PLACEMENT for microcurrents Work position Work position Work position Work position Work position Work position 33 37 38 39 40 41 42...
Page 34: ...ELECTRODE PLACEMENT with accessories Work position Work position Work position Work position Work position Work position 43 44 45 46 47 48 REV 03 09 04 34...
Page 35: ...ram check that the cables are connected and that the electrodes are positioned on the area to be treated In addition be sure that the electrodes are not worn because this could inhibit their ability t...
Page 36: ...GLOBUS ITALIA SRL Via Vittorio Veneto 52 31013 TV Tel 0438 7933 Fax 0438 793363 www globusitalia com info globusitalia com...