Congratulations with your GLOBE air motor!
This product is made with quality materials to meet the highest standards.
This manual contains safety instructions for the use of your GLOBE air
motor. Please read and follow all recommended instructions for a trouble-
free use.
Warranty
The GLOBE air motor is designed to operate without any problems. This is only guaranteed if the
regulations with regards to installation, operation, maintenance and repair are observed. Problems
occurring during the guarantee period are corrected in accordance to GLOBE Airmotors BV
guarantee conditions. All results of unauthorized replacements and alterations are at the operator’s
expense. In case of unauthorised opening and repair work carried out during guarantee period by
the operator, the guarantees may become invalid.
You can order your service kit at [email protected]. Please ensure that maintenance is carried
out by certified staff.
Safety first
Safety is important for you and other people. For the protection of you and others, we have several
warnings in this manual and on the product. Please always read carefully and follow the instructions.
STOP
Hazard
Possible consequences: dead or
severe injuries
Dangerous situation
Possible consequence: damage
to the drive of the environment
Wear hearing protection
Wear eye protection
Important instructions
on protection against
explosion
Hazard Situation
Possible consequences: slight or
mild injuries
APPROVALS
ATEX CERTIFICATION
II 2G Ex h IIC T4 Gb
II 2D Ex h IIIC T135°C Db
In which:
II
2G
2D
Ex h
IIC
IIIC
T4
T135°C
Gb
Db
Ta
Equipment group II for use above ground
Category 2G for use in Zone 1 or 2
Category 2D for use in Zone 21 or 22
Protection by constructional safety “c” Gas
group IIC
Dust group IIIC
Temperature class T4
Maximum surface temperature 135°C
Equipment protection level Gb
Equipment protection level Db
Ambient temperature range
Ta = - 20° + 60°C
Contents
Warranty 3
Safety first
3
Checklist to comply to ATEX
4
Installation
5
Mounting to construction
5
Air supply
6
Operation
8
Performance regulation
10
Maintenance
11
Summary of the hazards with
protective means:
12
Shutdown and long storage
12
Rebuild instructions
13
Trouble shooting
14
Performance VA1X
15
Main dimensions VA1X
16
Exploded view with spare parts list
16
Ordering code
17
ATEX Certification
18
CE Certification
19
The GLOBE vane air motors are ATEX certified
according to the following (harmonized)
standards:
EN-ISO80079-36:2016
EN-ISO80079-37: 016
The motors are marked with the following EX
marking: