Page 28
SmartOne C User Manual
Confidential & Proprietary Information
9100-0410-01 R2.4
UNDESIRED STATE MESSAGE
• Input 1/Input 2 -
The SmartOne can be configured to send messages throughout the time the input is in the
undesired state, either to the Open or Closed position. The message interval while the input is active can be
configured in Days, Hours, and Minutes. Once the input exits the undesired state, the SmartOne will return to
the message interval or time (s) of day for Location Messages.
• Vibration -
If Vibration is Enabled, the SmartOne can be configured to send a Undesired State Message once
the device is in a state of vibration or in a state of lacking vibration. The message interval, while selected
undesired state is active, can be configured in Days, Hours, and Minutes.
ACCUMULATE/COUNT MESSAGE
• Input 1/Input 2 -
The SmartOne can accumulate hours and/or count events while input 1 or input 2 is enabled.
The SmartOne can send an accumulate/count message once the configurable intervals are specified in days,
hours, and minutes.
• Vibration -
If Vibration is Enabled, the SmartOne
can accumulate hours once the device enters a
state of vibration or lacks a state of vibration. The
SmartOne can send an accumulate message once
the configurable intervals are specified in days,
hours, and minutes.
NOTE:
SOV = State Of Vibration; SOLV = State Of Leaving Vibration