Globalsat LoRa LM-110H1 User Manual Download Page 17

 

17 

 

 

Federal Communication Commission Interference Statement 

 

This  device  complies  with  Part  15  of  the  FCC  Rules.  Operation  is  subject  to  the 

following two conditions: (1) This device may not cause harmful interference, and (2) 

this  device  must  accept  any  interference  received,  including  interference  that  may 

cause undesired operation. 

 

This  equipment  has  been  tested  and  found  to  comply  with  the  limits  for  a  Class  B 

digital  device,  pursuant  to  Part  15  of  the  FCC  Rules.    These  limits  are  designed  to 

provide reasonable protection against harmful interference in a residential installation. 

This  equipment  generates,  uses  and  can  radiate  radio  frequency  energy  and,  if  not 

installed and used in accordance with the instructions, may cause harmful interference 

to  radio  communications.    However,  there  is  no  guarantee  that  interference  will  not 

occur in a particular installation.    If this equipment does cause harmful interference to 

radio  or  television  reception,  which  can  be  determined  by  turning  the  equipment  off 

and on, the user is encouraged to try to correct the interference by one of the following 

measures: 

 

 

Reorient or relocate the receiving antenna. 

 

Increase the separation between the equipment and receiver. 

 

Connect the equipment into an outlet on a circuit different from that 

to which the receiver is connected. 

 

Consult the dealer or an experienced radio/TV technician for help. 

 

FCC Caution: 

 

Any changes or modifications not expressly approved by the party responsible for 

compliance could void the user's authority to operate this equipment. 

 

This transmitter must not be co-located or operating in conjunction with any other 

antenna or transmitter. 

 

FOR MOBILE DEVICE USAGE (>20cm/low power) 

Radiation Exposure Statement:

 

This  equipment  complies  with  FCC  radiation  exposure  limits  set  forth  for  an 

uncontrolled  environment.  This  equipment  should  be  installed  and  operated  with 

minimum distance 20cm between the radiator & your body. 

 

 

Summary of Contents for LoRa LM-110H1

Page 1: ...ation 16F No 186 Jian 1 st Rd Zhonghe Dist New Taipei City 23553 Taiwan Tel 886 2 8226 3799 Fax 886 2 8226 3899 lora globalsat com tw www globalsat com tw USGlobalSat Incorporated 14740 Yorba Court Ch...

Page 2: ...TENTS Product Description 3 Product Feature 3 Hardware Specifications 4 Pin Definition 5 Product Size 5 LoRaWAN Configuration 6 MOST Link Configuration 7 Federal Communication Commission Interference...

Page 3: ...ard LoRaWAN FW and proprietary MOST Link FW in the same module Default as LoRaWAN switch to MOST Link by AT command Share same PCB device design for both LoRaWAN and private RF data communication For...

Page 4: ...dBm Transmission Media UART UART Baud Rate 57600 bps Parity 8N1 Operation Voltage 3 6 V Current Consumption Receiving 21 mA Transmitting 125 mA Sleeping 5 uA Transmission Distance 1KM 10KM 980 bps Rec...

Page 5: ...cription 1 GND GND Ground 2 VCC Input 3 0 6 0 V 3 RXD Input UART input 4 TXD Output UART output 5 BZ Output Module s operation status 6 P2 Input Pin2 for switching operation mode 7 P1 Input Pin1 for s...

Page 6: ...ation Activation by personalization directly ties an end device to a specific network by passing the join request join accept procedure Activating an end device by personalization means that the DevAd...

Page 7: ...ions setting up under MOST Link Under this protocol the default mode is Disable P0 0 which is the payload data transmission in transparent It only supports command A0 A1 for AES128 encryption function...

Page 8: ...r is not valid Note 1 In Wake up mode LM 130H1 stays awake and send wake up code i e Normal mode plus with preamble byte while transmitting data 2 In Power saving mode LM 130H1 sleeps all the time Sen...

Page 9: ...Read LoRa Firmware Version Command Description AAT1 L2 Response Firmware version 16 Bytes Example F 0LR 14 1704191 Set LoRa Group ID Command Description AAT1 L3 parameter Parameter The number of LoRa...

Page 10: ...15MHz and Tx frequency as 915MHz The command is AAT1 L4 915000 915000 Read Rx Tx Frequency of LoRa Channel Command Description AAT1 L4 Response Rx frequency in KHz Tx frequency in KHz Set Data Rate of...

Page 11: ...of LoRa Channel s Tx Power Command Description AAT1 L7 parameter Parameter Index of Tx power from 0 to 7 0 5dBm 1 7dBm 2 9dBm 3 11dBm 4 13dBm 5 15dBm 6 17dBm 7 20dBm Default 7 Response ok parameter i...

Page 12: ...first one responding if the command is valid or not After the payload is sent out it would get the second response 1st Response ok parameter is valid invalid_param parameter is not valid 2nd Response...

Page 13: ...sponding if the command is valid or not After the payload is sent out it would get the second response 1st Response ok parameters are valid invalid_param parameter is not valid 2nd Response TX_OK payl...

Page 14: ...get the second response 1st Response ok parameters are valid invalid_param parameter is not valid 2nd Response TX_OK payload is sent out TX_NO_ACK payload is sent out but not get ACK TX_BUSY payload i...

Page 15: ...ryption Status Command Description AAT3 A0 Response 1 Enable AES128 Encryption 0 Disable AES128 Encryption Set AES128 Encryption Command Description AAT3 A1 parameter Parameter AES128 Key in hexadecim...

Page 16: ...es number of MOST Link while not getting ACK 0 9 0 disable Default 0 Parameter2 Timeout of getting ACK 1 255 seconds Default 3 Response ok parameter are valid invalid_param one or both parameter are n...

Page 17: ...tion If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interfe...

Page 18: ...uct In these circumstances the OEM integrator will be responsible for re evaluating the end product including the transmitter and obtaining a separate FCC authorization End Product Labeling This trans...

Reviews: