Warranty and Return Policy

All GlobalMedia Group, LLC (GMG) products are warranted under the 
following terms:

Products that become defective during the first year after the order is 
shipped will be repaired or replaced by GMG free of charge. This limited 
warranty is contingent upon proper use of the product and does not cover 
products that have been damaged (scratches, bent metal, broken 
components) misused, modified, or subject to unusual physical or electrical 
stress. All returns for any other reason must be made within the first 30 
days from time of shipment and will be subject to a 25% restocking charge. 
Buyer must include all original components, literature, and packaging in the 
same salable condition received to avoid any additional charges.

All returned materials must have a GMG return materials authorization 
(RMA) number. Authorized returns must be shipped freight prepaid to 
GMG. GMG reserves the right to refuse any return that is sent COD or 
without an RMA number visible on the exterior of the package. 
Unauthorized returns, refused shipments, and authorized returns of 
nondefective merchandise after the above stated return periods are subject 
to additional charges. 

Limited Liability Agreement

No claim made by the buyer shall be for an amount greater than the 
purchase price of the goods in respect of which the claim was made, 
regardless of whether the claim pertains to damage incurred in shipping, 
failure to ship, or inherent defects. GlobalMedia Group will in no way be 
liable for incidental or consequential charges. In all events, GMG reserves 
the option of repair or replacement at its discretion. GMG takes no 
responsibility for incorrect, outdated, or otherwise inaccurate information, 
including pricing and product specifications. GMG is not responsible for 
typographical errors or omissions and shall not be liable for any incidental 
or consequential damages caused directly or indirectly from any GMG 
product. In addition, GMG reserves the right to change prices, 
specifications or discontinue products at any time without prior notice while 
reserving the right to refuse or conduct a cancellation on its transaction 
activities due to price inconsistency from its suppliers. 

©2002-2017 GlobalMedia Group, LLC All Rights Reserved.

Summary of Contents for WallDoc Beta

Page 1: ...MAN 600402 Rev B 3 22 17 WallDoc Beta Installation and User Manual...

Page 2: ...tellectual property rights is granted by this document whether express or implied by estoppel or otherwise One or more GlobalMed products are covered under U S Patent s with other patents pending Any...

Page 3: ...of the package Unauthorized returns refused shipments and authorized returns of nondefective merchandise after the above stated return periods are subject to additional charges Limited Liability Agre...

Page 4: ...use exam cameras on the market and eNcounter eNcounter is an open architecture singular platform incorporating best in breed devices healthcare delivery systems and peripheral aggregation capabilities...

Page 5: ...ial Revision History Table 1Revision History table Revision Changes Date B Consolidated installation instructions for both with and without codec Consolidated installation instructions and user manual...

Page 6: ...No MAN 600402 Rev B vi Confidential Table of Contents Chapter 1 WallDoc Beta Installation Overview 1 Mounting WallDoc Beta 2 Chapter 2 Using WallDoc Beta Device Storage 16 Southco Keypad 17 Cleaning P...

Page 7: ...make sure you have all the items Six HD wall anchors Six 1 4 20 x 2 flat head Phillips screws Two 5 16 18 x 1 hex head bolts Four 5 16 flat washers Two 5 16 nuts Two Allen wrenches one large one smal...

Page 8: ...1 2 Mounting WallDoc Beta 1 Place the mounting bracket on the wall where WallDoc Beta will be installed 2 Measure 36 1 2 inches with a tape measure from the floor to the bottom edge of the mounting p...

Page 9: ...3 Confidential 3 Trace out all eight screw points as seen in Figure 3 4 To drill the holes and place the anchors Caution Use a stud finder to locate the studs and cable channels Figure 2Measure the m...

Page 10: ...hrough all eight screw points traced on the wall b Insert plastic toggle anchors see Figure 4 into six of the eight drilled holes the left three and right three holes c Grip the plastic toggle and pus...

Page 11: ...ng plastic from the anchor see Figure 5 5 To secure the armature bracket to the mounting plate Caution Make sure to insert three of the 1 4 20 FH bolts into the left three screw points before securing...

Page 12: ...the armature bracket on to the left two screw holes of the mounting plate as seen in Figure 6 Bolts are provided in the same box with the armature bracket b Use a ratchet with socket size and a wrench...

Page 13: ...rs and use 20 FH bolts to screw the plate in place see Figure 7 7 To attach the WallDoc Beta armature and the network switch bracket Note Not everyone has the Cisco SX20 codec network switch and the a...

Page 14: ...t the WallDoc armature into the armature bracket of the mounting plate see Figure 8 b Mount the network switch bracket to the upper right corner with two 8 32 x 3 8 Phillip head screws see Figure 8 an...

Page 15: ...e Cisco SX20 codec Note Not everyone has the Cisco SX20 codec as part of their WallDoc Beta package If you do not have the Cisco SX20 codec proceed to Step 10 a Use four of the provided screws that co...

Page 16: ...the mounting plate using the network switch bracket attached in Step 7b see Figure 11 9 To secure the Cisco SX20 codec and Steth IP to the mounting plate a Remove two of the screws located behind the...

Page 17: ...the bottom screw hole see Figure 12 d Once the bracket is attached to the Cisco SX20 codec place it all on to the mounting plate and use two 8 32 x 3 8 Phillip head screws to secure it in place see Fi...

Page 18: ...two 8 32 x 3 8 Phillip head screws to secure the power strip on the mounting plate see Figure 14 11 To attach the WallDoc to the armature Caution Use a two man lift to lift the WallDoc Beta out of th...

Page 19: ...thin the blue bag to tighten down the armature Rotate clockwise to tighten d Use the smaller Allen key within the blue bag if the WallDoc has too much play and doesn t rest well freely Rotate counter...

Page 20: ...on codec versions are shipped with the power strip on the back of the WallDoc Beta 13 To mount the main camera a Place the main camera at the top of the WallDoc Beta see Figure 18 Figure 17 Plug in th...

Page 21: ...Doc No MAN 600402 Rev B 15 Confidential b Use the provided screw to attach and tighten the camera to the top of the WallDoc Beta either from the front or backside see Figure 18 and Figure 19 Figure 1...

Page 22: ...evice storage compartment enter the default pass code C on the keypad see Figure 20 2 To change the default pass code see Southco Keypad on page 17 3 The inside of the WallDoc Beta storage compartment...

Page 23: ...s into one of four USB slots in the bottom right hand side of the WallDoc Beta see Figure 22 2 2 Southco Keypad The following figures provide the manufacturer s instructions for using the Southco keyp...

Page 24: ...Using WallDoc Beta 3 22 17 Doc No MAN 600402 Rev B 18 Confidential Figure 23 Southco instructions part A...

Page 25: ...Using WallDoc Beta 3 22 17 Doc No MAN 600402 Rev B 19 Confidential Figure 24 Southco instructions part B...

Page 26: ...Using WallDoc Beta 3 22 17 Doc No MAN 600402 Rev B 20 Confidential Figure 25 Southco instructions part C...

Page 27: ...DC GuidelinesforDisinfectionandSterilizationinHealthcareFacilities 2008 In order to stratify the relative degree of risk for infection when using the individual components the procedures are categoriz...

Page 28: ...iodine solution alcohol or chlorine Semi critical Cables and cords Gently wipe all of the exposed cables and cords with a disinfecting wipe and or soft cloth lightly moistened with a facility or CDC...

Page 29: ...ing wipe and or soft cloth lightly moistened with a facility or CDC approved cleaning solution Non critical Keyboard Gently wipe the table top keyboard with a disinfecting wipe and or soft cloth light...

Reviews: