V900-B1 GSM REMOTE CAMERA USER MANUAL
46
No.
General Trouble
Possible Reason
Solution
Didn’t set master user number
Set master number before
add sensor.
8
Can’t start the camera
after long time supply
with the battery.
Battery runs out of power.
Connect
the
camera
to
external AC power and charge
for at least one hour, then,
restart camera.
Note
: If
the problem can’t be solved with above guidelines, contact to your local
distributor or after service center.
Chapter 8 Main Technical Parameters
Power adaptor Input: 100V
~
240V/50Hz Output: 5.5V DC
Work temperature -10
℃
~
+45
℃
Store temperature -20
℃
~
+60
℃
Relative Humidity 10-90%
,
without condensation
Working band EGSM900
、
DCS1800 (GSM850
、
PCS1900 Optional)
Communication protocols GSM PHASE 2/2+ (including data operation)
Wireless sensor receiving code ASK
Wireless sensor receiving band 433MHz or 315 MHz
Max wireless sensor 15 units
Remote control receiving band 433MHz or 315 MHz
Effective distant of the remote control 10 meters (wide area)
Image format JPEG
Image resolution 160
×
128
、
QVGA320
×
240
、
VGA640
×
480
Camera pixel 300K pixel
Camera Shooting angel 68 degree
Best shooting distance at night
≤
6 meters
Lithium battery (Inner) 800mAh
Battery standby time 24 hours
(
Affected by network
)
Appendix: SMS commands list
Category
Function
Command
User
Define the
user
Add a master number to the
device
(1) #00#
Master
Change the master user’s
number
(2) #14#
NewMasterNumber
#
Master
Change the password
(3) #04#
oldpassword
#
newpassword
#
Master