Global IP Telecommunications
User name / account:
Please enter user name or user ID as requirded by your service provider.
Password / pin:
If your are using H323 with calling card please enter calling card's password. If you are using a md5
acount please enter its password. If dial plan selected, please enter an aditional # (e.g. 6234#).
Please enter your password or pin if you are using a SIP account. MGCP-protocol users please enter
Domain name. Net2phone needs password of Net2phone card.
Some MGCP system do need additional characters. The best would be if you do enter the domain in
brakets (e.g. “voiptest.com”).
Register port:
Please enter 2427 if using MGCP or 5060 (additional clients do need the port increased by 1 or 2 -
depends on service) if using SIP. If using H.323 or Net2phone you can use any port between 1024
and 65535.
Signal port:
5060 if using SIP or any TCP port between 1024 and 65535 if using H323.
Control port:
With H323 protocol used, this port is H.245 port using TCP protocol. Please enter a number between
1024 and 65535. .
Register ttl:
Timer for sending keep alive signal to either Gatekeeper or SIP Proxy. Default is 60. Value is specified
in seconds.
RTP type of service:
Set RTP packet priority. As higher the value as higher the priority.
RTP port / Voice:
RTP port is the port transferring and receiving voice flow using UDP protocol. Please fill an even
number between 1024 and 65535 into this field. Can not be the same like signal port.
Type of account:
Select an other value then "Auto" if using H323 and as specified by your provider.
SIP users will use "user name".
Call type:
Select either "normal" or "advanced".
DTMF signal transmission:
Set DTMF signal sending way by selecting control string, inband audio, signal keypad or rfc 2833 from
dropdown list..