![background image](http://html1.mh-extra.com/html/global/flogos-lite/flogos-lite_instruction-manual_2231996006.webp)
Flogos-lite
™
Flogos-lite™ Instruction Manual
Set Legs Into the Leg Locks
Lower the Inner Top until the legs rest on the Leg Locks located in each of the four corners of the
Lower Case. Guide each leg into the square hole in its Leg Lock. There are no locking mechanisms
to hold the legs into the Leg Locks. Each leg, though, must rest in the bottom of its’ repective Leg
Lock in order for the Inner Top to be properly leveled and for proper operation of the Flogos-lite.
Attach the helium hose to the fitting on the gas control
solenoid located on the lower side of the Controller
Enclosure. Using two 9/16” open end wrenches (included)
hold the fitting on the solenoid valve with one and tighten
the gas hose fitting with the other. This prevents undue
stress being placed on the solenoid valve which could dam-
age it.
The supplied regulator is a U.S. standard CGA-580 inert gas
fitting. If the supplied regulator cannont be used, and a
different regulator is used, make sure it is capable of a
steady 50 PSI output.
Do not adjust fitting.
Attaching the Helium Hose
3
©2011 Global Special Effects, Inc.