CAUTION:  

The fountain is rated for inlet water pressure of 20-105 PSI. A pressure reducing

regulator should be used if the inlet water supply exceeds 105 PSI. Any damage caused by

reason of connecting this product to supply line pressures lower than 20 PSI or higher than

105 PSI will void warranty.

START-UP

Initial water flow may have sputter due to air in the water lines; this will be eliminated

once air is purged from all water lines. Press and hold the push button until a steady

water stream is achieved.

STREAM HEIGHT ADJUSTMENT

To adjust the water stream height, insert a small flathead screwdriver through the access

hole in the center of the push button and turn the adjustment screw. Turn clockwise to raise

the stream height and counterclockwise to lower the stream height. For best adjustment,

the stream should be approximately 1-1/2" above the top of the bubbler, (see FIG.3).

FIG. 3

1 1/2''

•  Before freezing temperatures occur, turn off the water at the shut-off valve, disconnect

the water supply line tubing and blow out lines. Press down on push button to release any

air pressure that may remain in the lines.

•  Remove trap before winterization draining.

•  DO NOT allow water lines to freeze. Cracked or broken components due to freezing are

not covered by warranty.

DRAINING AND WINTERIZATION

Outdoor Wall Mounted Drinking Fountain

Summary of Contents for 761224

Page 1: ...or any leaks before use WARNING NOTE Included are the necessary vandal resistant stainless steel bolts and washers needed to anchor this unit to the wall Installer must provide a 1 1 2 PVC drain line if applicable and water supply line All connections are made inside the item through the access door as shown in the drawings It is recommended to install a shut off valve not included on the water su...

Page 2: ...r Wall Mounted Drinking Fountain COLOR OPTIONS WWW GLOBALINDUSTRIAL COM SS316 SS316 GREEN SS316 BLACK SS316 BLUE DRAIN PAN DRAIN BUBBLER PUSH BUTTON MOUNTING PLATE DRINKING FOUNTAIN Package Contents Fountain Bubbler Hardware Bag ...

Page 3: ...ad Screwdriver REQUIRED TOOLS H4 1 Bubbler SPECIFICATIONS Features 316 Stainless Laminar Flow Heavy Duty Vandal Resistant Finish SS Finish Black BK Blue BL Green GN Power No Electrical Required Bubbler Vandal Resistant Activation Type Push Button Mounting Type Wall Mount Product Dimensions 10 1 4 L x 16 1 4 W x 7 1 4 H Weight 21 lbs Installation Location Outdoor No of Stations 1 Outdoor Wall Mount...

Page 4: ... See Page 11 for Draining and Winterization Actual product configuration may vary based on model ordered 1 1 2 WASTE A 10 1 4 260mm 7 1 2 191mm 6 1 4 158mm 8 200mm 12 300mm 8 1 2 217mm 4 100mm 1 2 12mm HOLES 4 ORIFICE HEIGHT 10 1 2 274mm 7 174mm 3 70mm 7 177mm 5 127mm Outdoor Wall Mounted Drinking Fountain ...

Page 5: ... line may be necessary check local plumbing codes WARNING The fountain is rated for inlet water pressure of 20 105 PSI A pressure reducing regulator should be used if the inlet water supply exceeds 105 PSI Any damage caused by reason of connecting this product to supply line pressure higher than 105 PSI will void warranty Flat head anti theft screw M6 x 10 qty 8 1 REMOVE ACCESS PANEL To gain acces...

Page 6: ...ng and secure to wall using provided anchor kit H3 mounting hardware 2 INSTALL BUBBLER 2a Unscrew and remove nut and washers from Bubbler H4 2b Locate the hole on the drinking fountain pan surface Align and sandwich with the two washers and tighten the nut to secure the bubbler 2c Bubbler is now properly installed Anchor kit consists of 4 M10 Nuts 4 M10 Lock Washers 4 M10 Standard Washers 4 M10 An...

Page 7: ...s are preinstalled see below illustration for reference All water connections and drains must comply with local codes FRONT VIEW SIDE VIEW 3 8 O D Water Inlet preinstalled Water Flow Check Valve preinstalled 3 8 O D Water Inlet preinstalled Water Inlet Adapter preinstalled Install Shut off Valve Not Included Outdoor Wall Mounted Drinking Fountain ...

Page 8: ...ON If drinking fountain is being installed in areas where cold temperatures may occur water inlet lines are preinstalled with pipe insulation to help prevent freezing Installation of a trap on the water drain line may be necessary check local codes Always remove trap before winterization draining CAUTION Before freezing temperatures occur see Draining and Winterization section of this manual page ...

Page 9: ... below illustration for reference All water connections and drains must comply with local codes Installation of a trap on the water drain line may be necessary check local codes 10 5 8 Drain Tube preinstalled Confirm with local codes for trap and other drainage requirements Elbow Drain Connector preinstalled SIDE VIEW FRONT VIEW Outdoor Wall Mounted Drinking Fountain ...

Page 10: ...the Drain Tube to the Drinking Fountain Drain Drain Connector Drinking Fountain Drain Note Turn on water supply and check all connections for leaks and proper operation Reinstall the access panel using the 8 M6 x 10 flat head anti theft screws preciously removed from the fountain WARNING Flush all water supply lines thoroughly before initial use Outdoor Wall Mounted Drinking Fountain ...

Page 11: ... stream height insert a small flathead screwdriver through the access hole in the center of the push button and turn the adjustment screw Turn clockwise to raise the stream height and counterclockwise to lower the stream height For best adjustment the stream should be approximately 1 1 2 above the top of the bubbler see FIG 3 FIG 3 1 1 2 Before freezing temperatures occur turn off the water at the...

Reviews: