FEATURES

• Micro-computer programmed

   control panel with LCD display
• 3-speed fan operation
• Time setting function

Running Time

Starting Time

• Convenient remote control
• Specially designed 48" diameter fan
• Thick cooling pads measure 

1820 x 200 x 1640mm =

71.7"W x 7.9"D x 64.6"H

• 5" rubber casters with brakes

SPECIFICATIONS

Fan Diameter

48" 

Max Airflow (CFM)

35000 m3/h = 20615 CFM(ft3/min)

Power Supply / Frequency

115V / 60Hz

Power Consumption (Watts)

1180

Style

Axial 

Water Consumption (G/Hr)

10.5 - 13.2 

Water Capacity (Gal)

92

Dimension

77.55" x 36" x 89.40" 

Weight (lbs)

485

Media Pad Size (2x pads)

1820 x 200 x 1640mm =  

71.7"W x 7.9"D x 64.6"H

Operating Temperature

68 - 122°F

Cooling Capacity (Sq. Ft.)

5382

ABOUT THE PRODUCT

The Evaporative Air Cooler is a high-tech product which utilizes 

water evaporation and air movement to cool the air. The cooler 

consists of a fan, a corrugated and fluted paper media pad and 

a water supply sump and water circulation system that maintains 

the saturation of the media. As the moisture in the moving air 

evaporates there is a cooling effect. The water level in the sump, 

if manually filled, can be monitored by the sight tube on the front 

of the housing. For constant automatic feed the water level is 

controlled by a float valve in the sump tank.

        WARNING:

 

Before operating machine, please read instructions carefully.

Operate in the following conditions:
• 68-122°F Operating Temperature.
• MAX with 113°F Water Temperature.
• Area must be free from airborne pollutants and contaminant's.
• Ventilated, open environment with fresh air supply.
• Do not use an extension cord with this fan.
•  

Check the outlet that this fan is plugged into for correct 

polarity before using outlet.

• 

 

Do not open control box compartment. No serviceable 

parts inside.

•  Low Voltage less than 110V or High Voltage greater than 120V 

may cause damage to motor and electronic controls.

• Test GFCI breaker on cord before each use.
• 

 

Unplug fan before removing media pad. Fan can start 

unexpectedly due to the timer control feature.

• DO NOT use fan if power cord is damaged.
• DO NOT drive forklift, power trucks, or any vehicle over power cord.
•  If the product is not operating correctly, please refer to Troubleshooting 

Guide or contact Customer Service at 800-645-2986.

• Any modification to fan will void warranty.
• All repairs must be done by an authorized technician.
• Do not modify equipment or power cord; warranty will be voided.
•  Close supervision is necessary when any appliance is used by or 

near children.

This product contains chemicals which are known to the State of 

California to cause cancer, birth defects, or other reproductive harm.

Summary of Contents for 292750

Page 1: ...ter level in the sump if manually filled can be monitored by the sight tube on the front of the housing For constant automatic feed the water level is controlled by a float valve in the sump tank WARNING Before operating machine please read instructions carefully Operate in the following conditions 68 122 F OperatingTemperature MAX with 113 FWaterTemperature Area must be free from airborne polluta...

Page 2: ... pad Remove the filter by removing the screws Rinse the filter under running water to wash off dirt DO NOT use pressure washer Pull out the cooling pad and wash both sides under running water Note Never use pressurized water Note Never use liquid detergent This may damage the pad Open the drainage valve to remove remaining water and then clean the water tank thoroughly with a soft cloth to remove ...

Page 3: ...or el tubo de visión en la parte frontal de la carcasa Para que haya una alimentación automática constante el nivel del agua es controlado por una válvula de flotador en el depósito del sumidero ADVERTENCIA Antes de utilizar la máquina lea atentamente el manual de instrucciones Operar en las siguientes condiciones Temperatura de funcionamiento 68 122 F MAX con temperatura del agua de 113 F El área...

Page 4: ... quitando los tornillos Enjuague el filtro con agua corriente para eliminar la suciedad NO utilice una lavadora a presión Sacar el panel de enfriamiento y lavar ambos lados con agua corriente Nota Nunca utilice agua a presión Nota Nunca utilice detergente líquido Esto puede dañar la almohadilla Abra la válvula de drenaje para eliminar el agua restante y a continuación limpie el depósito de agua a ...

Page 5: ...r le tube de visualisation devant le compartiment Pour une alimentation automatique constante le niveau d eau est contrôlé par un régleur à flotteur à l intérieur du réservoir collecteur AVERTISSEMENT Avant de faire fonctionner veuillez lire attentivement les instructions Utilisez dans les conditions suivantes Température de fonctionnement de 20 50 C 68 122 F MAX avec une température de l eau 45 C...

Page 6: ...tirez le filtre en enlevant les vis Rincez le filtre sous l eau courante pour nettoyer la saleté N utilisez PAS de laveuse à pression Tirez sur le tampon refroidisseur et lavez les deux côtés sous l eau courante Remarque N utilisez jamais d eau sous pression Remarque N utilisez jamais de détergent liquide Ceci pourrait endommager le tampon Ouvrez la vanne de drainage afin de retirer le reste de l ...

Reviews: