BATTERY CHARGING (cont.)
1. Place charger and machine in a well ventilated area.
2. Turn machine off.
3. Open recovery tank up, exposing battery compartment
4. Check fluid level in each battery cell. DO NOT charge
batteries unless fluid is slightly covering the battery
plates. Do not overfill the batteries. Overfilling may
cause the batteries to overflow during charging due to
expansion. Replace the caps prior to charging.
5. Plug approved charger into grounded wall outlet
before plugging the charger into the machine.
6. Plug charger into red charger receptacle located in the
front left of the battery compartment.
7. Flip up the recovery tank "kick stand" and gently lay the
recovery tank down until it rests on the stand.
8. The charger will automatically begin to charge the
batteries, and it will automatically shut down once the
batteries are fully charged.
9. Upon completion of charging, first unplug the charger
from the wall outlet, and then disconnect the charger
from the machine.
10. Check the battery level after charging is complete. If
fluid level is low, add distilled water to bring the fluid
level up to the bottom of the sight tubes. Replace the
caps and wipe the batteries down with a towel.
PREVENTATIVE MAINTENANCE
DAILY MAINTENANCE
1. Remove pad driver / brush and clean with approved
cleaner.
2. Drain recovery and solution tanks completely and rinse
out with clean water. Visually check the recovery tank for
debris and clean out as necessary.
3. Raise squeegee assembly off floor and wipe it down
with a damp towel. Be sure to store the squeegee in the
up position.
4. Remove the float shut-off assembly and rinse it out with
clean water.
5. Clean machine with an approved cleaner and a damp
towel.
6. Recharge batteries.
WEEKLY MAINTENANCE
1. Check fluid level in batteries.
2. Check batteries for loose or corroded cables.
3. Keep battery tops clean from corrosion.
MONTHLY MAINTENANCE
1. Check machine for leaks and loose fasteners.
2. Lubricate all grease points and pivot points with silicon
spray and approved grease.
3. Place machine over a floor drain. Flush solution system
by pouring 3 gallons of hot water and approved alkaline
detergent into the solution tank and running machine
(with solution control on) for 45 seconds. Turn machine
off and let it sit overnight. The next day, drain the
remaining solution and rinse the solution tank out with
clean water.
MACHINE OPERATION CONTINUED
8
WARNING
Before performing any maintenance on
the machine, be sure that the power is turned off,
or the batteries are disconnected!
!
WARNING
Repairs are to be completed by
Authorized Service Centers only. Any repairs
completed by unauthorized persons will void the
warranty.
!
Summary of Contents for 261123
Page 11: ...MODEL 261123 261124 CONTROL HOUSING 11 PARTS LIST...
Page 13: ...MODEL 261123 261124 RECOVERY TANK ASSEMBLY 13 PARTS LIST...
Page 15: ...MODEL 261123 261124 SOLUTION TANK ASSEMBLY 15 PARTS LIST...
Page 18: ...MODEL 261123 261124 SQUEEGEE ASSEMBLY 18 PARTS LIST...
Page 20: ...MODEL 261123 261124 BRUSH LIFT AXLE ASSEMBLY 20 PARTS LIST...
Page 22: ...MODEL 261123 261124 SOLUTION CONTROL ASSEMBLY 22 PARTS LIST...
Page 24: ...MODEL 261123 261124 BRUSH SKIRT ASSEMBLY 24 PARTS LIST...
Page 26: ...MODEL 261123 261124 BRUSH PAD ASSEMBLY 26 PARTS LIST...