background image

 

 

DO NOT expose heater to rain/snowfall. 

 

The supply circuit must incorporate a double-pole isolating switch having a contact separation of at least 
1/8”. 

 

DO NOT operate if the power cord or plug is damaged, after a malfunction, or after the unit has been 
dropped or damaged in any manner. Disconnect power and have the heater inspected by a reputable 
electrician before reusing. 

 

Connect to properly grounded outlets only. 

 

It is important to maintain a minimum distance of 3-feet between the heater and curtains, or any other 
combustible materials that will be affected by the radiated heat. 

 

DO NOT touch the fireguard or reflecting cover when the heater is in use; do not insert any objects into the 
fireguard to prevent high temperature scalding. 

 

Heater is for outdoor use only. 

 

Outdoor weatherproof outlet is recommended. 

 

NEVER leave the heater unattended while it is operating. 

 

DO NOT run cord under carpeting, throw rugs, runners, or similar coverings. Do not route cord under 
furniture or appliances. Arrange cord away from high traffic areas and where it will not be tripped over. 

 

DO NOT let the power cable hang over the edge of a table/counter or let it come in contact with hot surfaces. 

 

DO NOT use an extension cord. 

 

To disconnect heater, turn controls to off, then remove plug from outlet. 

 

Disconnect heater during installation and maintenance. 

 

NEVER place hands under the heating elements. ALWAYS allow heating element to cool at least 10 minutes 
before touching the heating tube or adjacent parts.                             

 

The heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or 
flammable liquids are used or stored. 

 

NEVER dismantle the components of the heater or replace with components not offered or recommended by 
Global Industrial.

  

 
 

SPECIFICATIONS: 

Model: 

246718 

Voltage: 

110-120 VAC 

Wattage: 

1500W 

Hertz: 

60Hz 

Application: 

Outdoor 

Dimensions: 

35-1/2

”L x 3-1/2” W x 5-1/8”H 

Weight: 

6.6 lbs. 

Cord Length: 

6 ft. 

 
 
INSTALLATION 

 
Tools Required: 

1.  Power Drill and Drill Bits 
2.  Phillips Head Screwdriver 
3.  Hammer 
4.  Level 
5.  Pencil 

 
A wall mounting bracket is provided with the heater. Before drilling holes make sure the mounting 
surface (ceiling or wall) is solid and that there are no hidden water pipes or electric wires behind it. 
Allow a minimum of 20” from each side of the heater to the wall and 7.8-ft off the floor. 
 

Summary of Contents for 246718

Page 1: ... handles when moving this heater Keep combustible materials such as furniture pillows bedding papers clothes and curtains at least 3 feet from the front of the heater and keep them away from the sides and rear DO NOT insert fingers or objects into any of the openings Keep all objects a minimum of 3 ft away from the heater DO NOT cover the heater or put objects such as fabrics or combustible materi...

Page 2: ...e tripped over DO NOT let the power cable hang over the edge of a table counter or let it come in contact with hot surfaces DO NOT use an extension cord To disconnect heater turn controls to off then remove plug from outlet Disconnect heater during installation and maintenance NEVER place hands under the heating elements ALWAYS allow heating element to cool at least 10 minutes before touching the ...

Page 3: ... ceiling mounting DO NOT position the heater at an angle more than 90 or less than 45 The supply cable must be at the lower end of the heater if the heater is installed at an angle or vertically Keep the supply cord away from the body of the heater which will get hot during use DO NOT install the heater on an inflammable surface Observe the minimum safe distance between the heater body and the inf...

Page 4: ...Ceiling Mounted Installation ...

Page 5: ...he UP and DOWN buttons to increase or decrease the heating level 5 TIMER BUTTON To set the timer from 0H 9H which is the number of hours it will run 0H will display and then adjust to the number of hours you would like to set using the UP and DOWN buttons Note All Global Industrial 246718 heaters and their remote controls have the same frequency so it is possible to control several heaters with ju...

Page 6: ...st once a month Clean as needed 11 The frequency of maintenance checks may be increased considering the amount of the dust in the environment 12 Check the condition of the Reflector Wire and Frame visually while cleaning the appliance In case of deformation consult with a qualified electrician 13 Check the Power Cord and Plug visually while cleaning the appliance In case of damage consult with a q...

Page 7: ...ustrial for additional information The symbol on the product or in its packaging indicates that this heater may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and hu...

Reviews: