background image

12

AIR CONDITIONER FEATURES

TO ADJUST FAN SPEEDS:

Press     to select the Fan Speed in four steps-Auto, 
Low, Med or High. Each time the button is pressed, 
the fan speed mode is shifted.For some models, the
fan speed can not be adjusted under HEAT mode. 
On Dry mode,the fan speed is controlled at Low 
automatically.

TO SELECT THE OPERATING MODE:

To choose operating mode, press      Mode button.Each 
time you press the button, a mode is selected in a 
sequence that goes from Auto, Cool, Dry ,heat(cooling
only models without)and Fan. The indicator light beside 
will be illuminated and remained on once the mode is 
selected.  

To operate on Auto feature:

In this mode, the fan speed cannot be adjusted, it starts 
automatically at a speed according to the room 
temperature. 

To operate on Fan Only:

Use this function only when cooling is not desired,such 
as for room air circulation or to exhaust stale air(on 
some models). (Remember to open the vent during this 
function, but keep it closed during cooling for maximum 
cooling efficiency.) You can choose any fan speed you 
prefer.
During this function, the display will show the actual
room temperature, not the set temperature as in the
cooling mode.

To operate on Dry mode:

In this mode, the air conditioner will generally operate 
in the form of a dehumidifier. Since the conditioned 
space is a closed or sealed area, some degree of 
cooling will continue.

When you set the air conditioner in AUTO mode, it will 
automatically select cooling, heating(cooling only models 
without), or fan only operation depending on what 
temperature you have selected and the room temperature.
The air conditioner will control room temperature 
automatically round the temperature point set by you.

In Fan only mode ,the temperature is not adjusted.

The unit will initiate automatically the Energy Saver 
function under Cool, Dry, Auto(only Auto-Cooling and 
Auto-Fan) modes.

SLEEP FEATURE:

Press      Sleep button to initiate the sleep mode. In 
this mode the selected temperature will increase

O

O

(cooling) or decrease (heating) by 2 F/1(or 2) C 30 
minutes after the mode is s

  elected.T  he t emperature  

will then increase (cooling) or decrease (heating) b

  y  

O

O

another 2 F/1(or 2) C after an additional 30  minutes.
T

 his n

 ew t emperature w

 ill be m

 aintained f 

or 6 h ours

 beforei t r eturnsto  th e originally se lected tem

  perature.

This ends the Sleep mode and  the u

  nit w

  ill c

  ontinue

t o o

  perate  as originally programmed. The Sleep 

mode program can be cancelled at any time during 
operation by pressing the Sleep button again.

 Press      Check filter button to initiate theis feature.
 This feature is a reminder to clean the Air Filter for
 more efficient operation. The LED(light) will illumi-
 nate after 250 hours of operation. To reset after 
 cleaning the filter, press the Check Filter button and
 the light will go off.

CHECK FILTER FEATURE:

ENERGY SAVER FEATURE:

Press     Energy saver button to initiate this function.
This function is available on COOL, DRY, AUTO 
(only AUTO-COOLING and AUTO-FAN) modes.The 
fan will continue to run for 3 minutes after the 
compressor shuts off.The fan then cycles on for 2 
minutes at 10 minute intervals until the room 
temperature is above the set temperature, at which 
time the compressor turns back on and Cooling 
Starts.

FOLLOW ME FEATURE:

(on some models)

This feature can be activated from the remote 
control ONLY. The remote control serves as 
a remote thermostat allowing for the precise 
temperature control at its location.

To activate the Follow Me feature, point the remote 
control towards the unit and press the Follow Me 
button. T

If the unit does not 

receive the Follow Me signal during any 7 minutes 
interval, the unit will beep to indicate the Follow Me 
mode has ended. 

he remote display is actual temperature at 

its location. The remote control will send this signal 
to the air conditioner every 3 minutes interval until 
press the Follow Me button again.

     When the unit is on or off, first press       Timer button, the 
     TIMER ON indicator light illuminates. It indicates the Auto 
     Start program is initiated. 
     When the time of TIMER ON is displayed 

     Press or hold the UP or DOWN button to change the Auto 
     time by 0.5 hour increments, up to 10 hours,then at 1 hour 
     increments up to 24 hours.The control will count down the 
     time remaining until start. 
     The selected time will register in 5 seconds, and the system 
     will automatically revert back to display the previous 
     temperature setting or room temperature when the unit is 
     on.(when the unit is off,there is no display.)
     Turning the unit ON or OFF at any time or adjusting the 
     timer setting to 0.0 will cancel the Auto Start/Stop timed 
     program.
 

,press the Timer 

     button again, the TIMER OFF indicator light illuminates. 
     It indicates the Auto Stop program is initiated. 

TIMER: AUTO START/STOP FEATURE:

Light flashing

Follow

   Me

Summary of Contents for 240113

Page 1: ...air conditioner please read this manual carefully and keep it for future reference WINDOW WALL TYPE ROOM AIR CONDITIONER Before using your air conditioner please read this manual carefully and keep i...

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ...xcess heat generation It may cause electric shock or fire due to heat generation Incorrect grounding may cause electric shock It may cause fire and electric shock It may cause fire It may cause explos...

Page 6: ...ters maycause failure It contains contaminants and could make you sick Stop operation and close the window in storm or hurricane Do not use strong detergent such as wax or thinner but use a soft cloth...

Page 7: ...the windowis a triple track type with a screen panel included remove the screen completely before installation Be sure the air conditionerhas been securely and correctly installed according to the ins...

Page 8: ...on and these Installation Instructions for future reference The carton is the best way to store unit during winter or when not in use NOTE Preliminary Instructions Do the following before starting to...

Page 9: ...crew and Flat washer for window panels 3 4 or 1 2 inch Long Hex head Screw Safety Lock 1 2 inch Long screw and Locknut 3 4 inch Long Flat Head Bolt and Locknut Sill Angle Bracket Long hex head locking...

Page 10: ...dow filler panel frame into channel in the top angle and bottom rail Do both sides 4 Insert washer head locking 7 16 screws 2 into holes in top leg of filler panel frame see step 6 Do not totally tigh...

Page 11: ...1 Carefully raise window to expose filler panel locking screws Loosen screws so filler panels slide easily 2 Extend panels to fill window opening completely Tighten locking screws on top Fig 17 3 Ins...

Page 12: ...2 Prepare Wall 1 Prepare wall in frame construction including brick and stucco veneer Working from inside the room find wall stud nearest the center of area where air conditioner will be installed by...

Page 13: ...nnel resting on frame See Fig 6 Fig 5 Side Louvers 1 Long Wood Screw Fig 6 Refer to Step 5 of Window Mounting for assembly of support brackets A wooden strip nailed to the outside wall should be used...

Page 14: ...the Step 2 Prepare Wall illustrations but make it double framed on either side and install between masonry wall opening and cabinet Frame must be securely anchored to masonry wall opening This way gi...

Page 15: ...te on Fan Only section CLEAN AIR FEATURE on some models Press Clean Air button the ion generator is energized and will help to removepollen andimpurities from the air and trap them in the filter Sleep...

Page 16: ...elected temperature This ends the Sleep modeand the unit will continue to operate as originally programmed The Sleep mode program can be cancelled at any time during operation by pressing the Sleep bu...

Page 17: ...aker tripping The fan will continue to run during this time The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other press and hold th...

Page 18: ...ed Push plug firmly into wall outlet House fuse blown or circuit breaker tripped Replace fuse with time delay type or reset circuit breaker Plug Current Device Tripped Press the RESET button Problem A...

Page 19: ...ing Water dripping INSIDE when unit is cooling Improper installation Tilt air conditioner slightly to the outside to allow water drainage Refer to installation instructions check with installer Dirty...

Page 20: ...2020001B6619 The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...

Reviews: