AM
The modulated waveform consists of two parts: the carrier waveform and the
modulating waveform. In AM, the amplitude of the carrier waveform varies with
the instantaneous voltage of the modulating waveform. The parameters for the
AM are in Figure 2- 29
Press Mod
→
Type
→
AM, to enter the following menu.
Figure 2- 29 Table 2- 14 Menu Explanations of the AM Parameters
Term Explanation
Modulation Depth
The amplitude range (also called ‘Percentage Modulation’). Modulation depth
varies from 0% to 120%.
In the 0% modulation, the output amplitude is the half of the set one.
In the 100 modulation, the output amplitude is the same with the set
one.
Function
Menu
Settings Explanation
AM Freq
Set the modulating waveform frequency.
Frequency range: 2mHz~20kHz
(internal source only).
AM Depth
Set the amplitude range.
Type AM
Amplitude
modulation.
Shape
Sine
Square
Triangle
UpRamp
DnRamp
Noise
Arb
Choose the modulating waveform.
To change the carrier waveform
parameter, press Sine, Square, Ramp,
Arb