3.8. Example 8:Generate a Burst Wave
Generate a burst waveform of 5 cycles. The period is 3ms. Use internal trigger
and 0 degree phase.
Steps:
Set the sweep function:
Press Sine and choose the sine waveform as the burst function. The default
setting of the source is internal.
Set the frequency, amplitude and offset
1. Press Freq and choose Freq which will display in white color. Input ‘10’ from
the keyboard and choose the unit ‘kHz’ to set the frequency 10kHz.
2. Press Ampl to choose Ampl which will display in white color. Input ‘1’ from
the keyboard and choose the unit ‘Vpp’ to set the amplitude 1Vpp.
3. Press Offset to choose Offset which will display in white color. Input ‘0’ from
the keyboard and choose the unit ‘Vdc’ to set the offset 0Vdc
Set the sweep mode.
Press Burst
→
N Cycle, choose N Cycle Mode.
Set the burst period
Press Period, input ‘3’ from the keyboard and choose the unit ‘ms’ to set the
period 3ms.
Set the start phase
Press Start Phase, input ‘0’ from the keyboard and choose the unit ‘ °’ to set
www.
GlobalTestSupply
.com
Find Quality Products Online at: