17
Figure 9
Description
PB-507 provides two open-collector output pulsers, each with 1 normally-open
(NO) and 1 normally-closed (NC) output. When the pushbutton is released, the
circuit is in NC state, and when the pushbutton is pressed, the circuit is in NO
state. The corresponding green led will light.
6.6 Logic switches
Front-panel controls
Figure 10
shows the Logic switches controls on the front panel of the trainer.