25
8.9. Programming Dimensional Weight [DIM] Factors
Selecting the program button ( PROG ) allows the user to review or change any of the four stored DIM
factors used by the ExpressCube
TM
countertop computer to calculate dimensional weight.
Select the DIM factor that you wish to change and verify the correct units of measure (Metric or Imperial)
before entering the new value.
1) Select an Option
(
To program, press and hold “PROG” 1 second)
1. Change DIM Factor
2. Change Scanner Trigger
3. Change Device Number
4. Exit (or Press “PROG”)
2) Select the Unit Type
(Press buttons firmly when selecting)
1. Metric
2. Imperial
3. Go Back
4. Exit (or Press “PROG”)
3) Select the [
Imperial
] DIM Factor to change
1. 154.9
2. 192.0
3. 145.0
4. 105.1
5. Go Back
6. Exit (or Press “PROG”)
4) Input New DIM Factor to Replace “current number”
“New number”
5) Accept New DIM Factor “xxx.x”
1. Yes
2. No
The dimensional weight factors can only have four digits with the last digit representing units or
tenths. (e.g. 000.0 to 9999) Any entry of four or less digits will be assumed whole numbers unless a
decimal is used. The maximum dim factor setting is 276 in3/lb