background image

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Express

Cube

TM

 

Resolution Model 265R

 

User Guide 

_________________________________________ 

 

Version 2.0 

 
 
 
 

Oct. 2009 

 

 

Summary of Contents for EC-265R

Page 1: ...ExpressCubeTM Resolution Model 265R User Guide _________________________________________ Version 2 0 Oct 2009...

Page 2: ...estic and international patents both issued and pending U S Patent No 7321859 and 7373722 issued All ExpressCube SizeIt software and firmware is protected by domestic and international copyrights Expr...

Page 3: ...ertop Power up 15 6 1 Power up 15 6 2 Initial Power up System Check 15 7 User Programming 16 7 1 Summary 16 7 2 Using the ExpressCube Controller Keypad for Programming 16 7 3 Using the PC running Expr...

Page 4: ...ntertop PC Controller SizeIt is not working 35 10 5 ExpressCube Countertop Maintenance Codes 36 11 ExpressCube Weight Calibration Procedure 37 11 1 WARNING Performed by Authorized Personnel Only 37 11...

Page 5: ......

Page 6: ...ved care must be taken not to subject the folded back assembly to any twisting or impacts that could harm the hinge assembly 2 2 Location and Placement Refer to the specifications to obtain the outsid...

Page 7: ...A Carefully lift up the rear sensor panel 90 to the surface of the platform until the holes at the rear of both parts of the assembly line up B Insert the supplied four locking bolts into the back ass...

Page 8: ...ner Connect to handheld scanner not supplied The port is a male RS 232 serial interface Printer RS 232 male port provides ASCII data output for either a printer or direct data logging onto a hard driv...

Page 9: ...as a dedicated male RS 232 serial port for use with a handheld bar code scanner Handheld scanner not supplied The RS 232 connector should be securely connected to the appropriate connector on the Expr...

Page 10: ...to the printer refer to the Technical Data Summary in the appendix of this manual 3 6 Connection of the Ethernet LAN Option A physical LAN port has been accommodated on the rear connector panel of all...

Page 11: ...sCube external device ports use RJ 11 four wire connectors Place or mount the device to be connected in the location that it will be used Insert the RJ connector until an audible click is heard Carefu...

Page 12: ...nel The cable from the rear of the unit to the adapter should be free from obstruction and located to prevent accidental removal from ExpressCube or the outlet Securely connect the power plug into an...

Page 13: ...f the SizeIt software is not required Proceed to the power up section of this user guide 4 2 Computer Control The use of a computer to control the ExpressCube Countertop system will require the instal...

Page 14: ...ive of the computer 3 Click the Windows START button and select RUN 4 Use the browse key to locate and select the set up file on the CD ROM drive 5 Run the selected file Note if you encounter recurrin...

Page 15: ...therboard enters a self diagnostic routine in which errors are reported in a diagnostic log The results of the diagnostic routine contain a summary of the polling the different subsystems of the Expre...

Page 16: ...be retained even if the ExpressCube countertop system is not powered 7 2 Using the ExpressCube Controller Keypad for Programming The ExpressCube Controller keypad has been designed to easily make adj...

Page 17: ...Menu 7 5 1 Alter Dimensional Weight DIM Factors Selecting this menu allows the user to review or change any of the four dimensional factors used by the ExpressCube countertop computer to calculate dim...

Page 18: ...d the measurement the user will press the trigger of the handheld scanner if equipped The ExpressCube will record the measurements and automatically send the acquired data with the bar code as if the...

Page 19: ...mber can be used to track a box through a facility Sub menu CURRENT DEVICE NUM XXX 000 999 If device number requires change from the current number type in the three digit new device number When the n...

Page 20: ...ean and free of dust build up to ensure optimum operating performance 8 2 Main unit LED indicators The main unit LED indicators are a set of four LEDs mounted on the front of the main platform of the...

Page 21: ...d helpful points presented in the manipulation of the package will be useful 8 4 Preparation for Measurements The ExpressCube countertop unit should be powered up and the ExpressCube control panel dis...

Page 22: ...e side of the box is in contact with the rear face The orientation of the box is arbitrary as long as it Sits over the center array Is flush contact to the back Sits within the yellow guide lines The...

Page 23: ...vent weight resolution If the dimensions cannot be resolved all dimensions will read N A If a cuboidal package is placed within the yellow guidelines and there is not a valid dimension obtained the pr...

Page 24: ...al location 2 Place the device to be connected in the location that it will be used 3 Carefully route the cable and insert the RJ 11 connector into either one of the two ExpressCube external device po...

Page 25: ...r 2 Change Scanner Trigger 3 Change Device Number 4 Exit or Press PROG 2 Select the Unit Type Press buttons firmly when selecting 1 Metric 2 Imperial 3 Go Back 4 Exit or Press PROG 3 Select the Imperi...

Page 26: ...allows faster weight and dimension acknowledgement and eliminates the need to wait for the Valid numbers to settle in first as required previously D Calibrate DIM Banks A very important addition to th...

Page 27: ......

Page 28: ...user should refer to Section 8 7 and verify that the box is properly positioned for measurement If the box is removed from the platform without the SEND PRINT button activated the acquired data will...

Page 29: ...7 To acquire and record the measurement of the box on the ExpressCube countertop the handheld scanner will activate the Acquire and SEND PRINT sequence while reading the bar code on the package The Ex...

Page 30: ...30 The successful acquired and sent measurement display for both of the ExpressCube control panels is illustrated below ExpressCube SizeIt Display ExpressCube Controller Display...

Page 31: ...ackage over hang as possible The ExpressCube countertop will automatically reconfigure itself as a weigh scale when an object is detected on the platform that cannot be accurately dimensioned The Expr...

Page 32: ...om the sensing strips Use a damp cloth with a mild detergent and rinse with a clean damp cloth Hand pumped sprayers can be used Apply a non corrosive cleaner to stubborn areas but care should be exerc...

Page 33: ...sembly is sealed to preserve the integrity of this measuring instrument There are a number of problems that may arise that can be addressed without tampering with the seals which are reviewed in this...

Page 34: ...ssCube Countertop Controller LCD display is not working Symptom The LCD display on the Controller either does not display any intelligent characters or cannot control the ExpressCube Countertop Check...

Page 35: ...B cable until a tone is heard from the computer Put in the USB and wait for a computer tone again Restart the SizeIt software 3 If the SizeIt program is still indicating that there is not USB connecti...

Page 36: ...mputer and the ExpressCube device has numerous errors or intermittent 1 Check connection 2 Check cable 3 Authorized Service 04 Scale Unstable Unable to obtain stable readings from load cell 1 Check th...

Page 37: ......

Page 38: ...ose any part or component manufactured by another manufacturer This warranty does not apply to any part or component which is used or rebuilt Global Sensor Systems Inc obligation and liability under t...

Page 39: ...ty This agreement shall not apply to equipment or components which has have A Been the subject of repairs or modifications not authorized by Global Sensor Systems Inc B Not been operated under normal...

Page 40: ...known as volume weight is the minimum weight that a package a given size may have that is handled by a carrier A carrier may state that any package of one cubic foot 12 x12 x12 will have a minimum we...

Page 41: ...n3 10 lbs 10 lbs 10 lbs 172 8 in3 lb Finding a DIM Factor using cm kg Find DIM factor if each cubic meter 100cm x 100cm x 100cm has a minimum weight allowance of 200 kg 1 m3 100cm x100cm x100cm 100000...

Page 42: ...g x 0 027679913 Some DIM Factors maybe provided in both units such as the IATA value of Dim Factor 166 in3 lb or Dim Factor 6000 cm3 kg These have been slightly modified for ease of application The Ex...