LGR Dehumidifier Low-Grain Refrigerant

 

200 Pints Per Day Water Pump

060617

globalindustrial.ca

Distribucion Industrial Globales S DE RL DE CF

User manual

Manual del usuario

Manuel de l'utilisateur

Customer Service

US: 1-800-645-2986

Servicio de atención al Cliente

México: 01.800.681.6940

Service à la clientèle

Canada: 888-645-2986

Technical Specifications

Width

21.3in

Depth

21.3in

Height

31.9in

Weight

104lb.

CFM

306

Amp

9.5

AHAM Rated, Capacity

100 Pints/day

90°F / 90% RH Capacity

200 Pints/day

Drain hose length

27 ft.

Cord length

25 ft.

Stackable

Yes

Control

Digital

Construction

Rotomolded PE

Built in pump

Yes

Refrigerant

R410A

Refrigeration

Low-Grain

IMPORTANT INSTRUCTIONS, SAVE FOR FUTURE REFERENCE

Note: When using electrical appliances, please follow these basic precautions to 

reduce the risk of fire, electric shock, and personal injury or property damage. 

All refrigeration products contain refrigerants, which under federal law must be 

removed prior to disposal.

 

  1.  Operate the unit from a power source of equal voltage, frequency, and rating as 

indicated on the product identification plate. 

  2.  Extreme caution and supervision is necessary when unit is used near children and 

pets or when left operating while unattended.

  3.  Do not operate unit if cord/plug has been dropped or damaged in any manner.  
  4.  Do not obstruct inlet or outlet openings. Do not operate in close proximity to walls, 

curtains, or other objects that may block inlet and outlet.

  5.  This unit must be plugged into grounded outlet.
  6.  To reduce the risk of electric shock, do not expose unit or power cord to moisture.
  7.  Always turn off and unplug unit prior to performing routine maintenance, or when 

not in use.

  8.  The use of attachments or accessories is not recommended or intended 

for use with product.

  9.  This product is intended for normal commercial use only. 
10.  Do not attempt to dismantle the appliance. 
11. Do not operate unit on a metal surface. 
12. Do not clean the appliance with any chemicals. 
13. This unit is not intended for hazardous locations. 

Circuit Diagram

Handle

Filter

Air intake 

metal grill

Air outlet

Drain hose

Wheel

Power cord

Cord wrap

Drain hose 

connector 

(male)

Control panel

Rating

label

Parts List

        WARNING:

 

Please read all instructions before using 

this dehumidifier.

Summary of Contents for LGR

Page 1: ...frequency and rating as indicated on the product identification plate 2 Extreme caution and supervision is necessary when unit is used near children and pets or when left operating while unattended 3...

Page 2: ...Selects and activates a function or setting PURGE Empties the water reservoir POWER ON OFF Turns the unit ON and OFF To ensure dehumidifier operates at its most efficient condition unit will be in de...

Page 3: ...e LCD screen will display the following message The water pump will turn on automatically and run for 40 seconds to drain the residual condensate water in the dehumidifier To avoid water spillage DO N...

Page 4: ...R2 ER4 Error message Coil sensor error Humidity sensor error Water pump fault or blockage Display Reading Flashes one time per second Flashes one time per second Flashes one time per second Cause 1 Co...

Page 5: ...cuando la unidad est siendo utilizada cerca de ni os y mascotas o cuando est funcionando sin supervisi n 3 No opere la unidad s el cable enchufe se han ca do o est n da ado de alg n modo 4 No obstruy...

Page 6: ...AMBAS teclas de ajuste hacia arriba y hacia abajo al mismo tiempo ENTRAR Selecciona y activa una funci n o configuraci n LAVADO Vaciar el tanque del agua ENCENDIDO APAGADO Encender ON y apagar OFF la...

Page 7: ...nte mensaje La bomba de agua se encender autom ticamente y funcionar 40 segundos para drenar los residuos del agua condensada en el deshumidificador Para evitar que el derrame de agua mueva el deshumi...

Page 8: ...de Global Industrial CODE ER1 ER2 ER4 Mensaje de Error Error en el sensor del Serpent n Error en el sensor de humedad Un fallo en la bomba de agua o hay un bloqueo La lectura de la Pantalla Destella...

Page 9: ...onner l unit si le cordon ou la prise est endommag ou a t chapp ou endommag de quelque fa on 4 Ne pas obstruer les ouvertures d entr e ou de sortie Ne pas utiliser proximit de murs rideaux ou autres o...

Page 10: ...en m me temps ENTREZ S lectionne et active une fonction ou un r glage PURGE Vide le r servoir d eau ALIMENTATION ON OFF Tourne ou teindre l appareil Pour assurer que le d shumidificateur fonctionne sa...

Page 11: ...he pour teindre l unit L cran LCD affichera le message suivant La pompe eau s allumera automatiquement et fonctionnera pendant 40 secondes pour purger l eau de condensation r siduelle du d shumidifica...

Page 12: ...1 ER2 ER4 Message d erreur Erreur du capteur de la bobine Erreur du capteur de la bobine Panne de la pompe eau ou un blocage Lecture de l affichage Clignote une fois par seconde Clignote une fois par...

Reviews: