Owner’s Manual

293149

TM

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain 
the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in 
personal injury and / or property damage! Retain instructions for future reference.

Global industrial Portable Air Conditi oners feature spot cooling 

for large areas where cooling of the enti re area is not practi cal. 

A dedicated spot cooling thermostat controls the unit in this ap-

plicati on.

These air conditi oners can also be used in smaller areas for room 

cooling.

Using the HEPA fi lter of grade H13, fi lter out dust with a size of

0.3 microns(

) A control panel provides ease of use and con-

tains a self-diagnosti c functi on and display, showing operati ng 

modes, room and set temperatures, and faults. 

If an abnormal operati on occurs, a visual display of the fault is 

shown. Caster wheels are included for easy portability. Suitable 

applicati ons include: a factory or work place, industrial kitchen, 

computer room, emergency cooling, outdoor event, etc.

Aft er unpacking the unit, carefully inspect unit for any damage that may have occurred during 

transit. Check for any loose, missing, or damaged parts.

Descripti on

Unpacking

Portable Air

Conditioners

293149

Figure 1

Owner’s Manual

293149

TM

Specifi cati ons

Model No.

Power Supply Ph-V-Hz

Cooling Capacity 

Btu/h

Power Con-

sumpti on Watt s

Rated Cur-

rent Amps

EER Btu/

Wh

293149

Single Phase, 115V, 60Hz

13,200

1,058

9.2

11.0

Model No.

Nema Plug

Power Cord 

Gauge AWG

Power Cord 

Length ft 

Dimensions 

W x D x H - in. (mm)

293149

5-15P

14

10

20.5 x 27 x 41.1 

(520 x 685 x 1044)

Summary of Contents for 293149

Page 1: ...l provides ease of use and con tains a self diagnostic function and display showing operating modes room and set temperatures and faults If an abnormal operation occurs a visual display of the fault i...

Page 2: ...verload protector Anti freezing thermister Full drain tank switch Automatic restart Power interruption Compressor time delay pro gram High pressure switch Features Temperature control Self diagnostic...

Page 3: ...substances to come into contact with the unit 13 DO NOT operate the unit in the presence of flammable substances or vapors such as alcohols pesticides gasoline etc 14 DO NOT use the plug to start and...

Page 4: ...ed 22 Only use in the upright position on an even flat surface Unit must be positioned at least 24 inches 60 cm from the nearest object in any direction 23 Stop operation immediately if abnormal noise...

Page 5: ...itioner as shown in Figure 4 1 Remove cool air outlet hose s from carton 2 Place the cool air outlet hose s on the front top of air conditioner 3 Use screws enclosed inside of box with cool air outlet...

Page 6: ...oreign material The unit is equipped with an approved NEMA plug configuration 292660 5 15P 292661 5 20P 292662 6 15P The appropriate outlet must be used for each plug type WARNINGS REGARDING PROPER LO...

Page 7: ...e the product Press the power button for 2 seconds while driving to stop the product Self diagnosis will be performed to test for abnormalities after marking VER for 3seconds when power is ON And the...

Page 8: ...des and operates in circulation LOW HIGH AUTOIn LCD the middle wing of each mode rotate and operate AUTO MODE If the power source becomes on after off it operates as auto and then as high or low depen...

Page 9: ...mode 1 It s the off reservation mode Press the time button for 2 seconds select the blower button and select on off minutes as the up down button You can choose to make a reservation for turning it o...

Page 10: ...in the guide and slide the filter up until the bottom of the filter clears the frame Then push the bottom of filter into the guide and let filter gently fall inside the guide NOTE For effective cooli...

Page 11: ...occurs and a code is displayed on the control panel The compressor and condenser fan motor will stop operating The evaporator fan will con tinue to run for 3 minutes If the fault is rectified within 3...

Page 12: ...rm Condensate tank is full Empty the water tank After installation of the water tank press the SPOT COOL or ROOM COOL button to resume operation Drain pump alarm Drain pump defective or improper hose...

Page 13: ...r has a loose or broken connection Contact a qualified service agent Abnormal tempera ture sensor value TH3 Prevention of Freeze Sensor open circuit or poor connection Contact a qualified service agen...

Page 14: ...2 COM L H COM L H COM CP N 1 L 1 PU PU1 CP2 COM EMC L H FUSE ALARM COM NO NC CP CP1 HP1 HP MOTOR LCD OUT TH1 LP1 LP TH2 TH3 ON OFF T AC S R FUSE TH1 TH1 OUT_TEMP SENSOR TH3 TH3 ICE_TEMP SENSOR TH2 TH...

Page 15: ...if the filter is dirty and not regularly cleaned 1 Clean the filter 2 Compressor will not work if the unit is turned off and on quickly 2 Wait 2 minutes after unit is turned off before turning the uni...