LIMITED WARRANTY

Global industrial ONE-YEAR LIMITED WARRANTY.

 Global industrial PORTABLE AIR CONDITIONERS, MODELS 

COVERED IN THIS MANUAL, ARE WARRANTED BY Global industrial TO THE ORIGINAL USER AGAINST DEFECTS 

IN WORK MANSHIP OR MATERIALS UNDER NORMAL USE FOR ONE YEAR AFTER DATE OF PURCHASE. ANY PART 

WHICH IS DETERMINED TO BE DEFECTIVE IN MATERIAL OR WORKMANSHIP AND RETURNED TO AN AUTHO-

RIZED SERVICE LOCATION, Global industrial DESIGNATES, SHIPPING COSTS PREPAID, WILL BE, AS THE EXCLU-

SIVE REMEDY, REPAIRED OR REPLACED BY Global industrial OPTION. FOR LIMITED WARRANTY CLAIM PROCE-

DURES, SEE “PROMPT DISPOSITION” BELOW. THIS LIMITED WARRANTY GIVE PURCHASERS SPECIFIC LEGAL 

RIGHTS WHICH VARY FROM JURISDICTION TO JURISDICTION.

LIMITATION OF LIABILITY. 

TO THE EXTENT ALLOWABLE UNDER APPLICABLE LAW, Global industrial LIABILITY 

FOR CONSEQUENTIAL AND INCIDENTAL DAMAGES IS EXPRESSLY DISCLAIMED. Global industrial LIABILITY

IN ALL EVENTS IS LIMITED TO AND SHALL NOT EXCEED THE PURCHASE PRICE PAID.

WARRANTY DISCLAIMER.

 A DILIGENT EFFORT HAS BEEN MADE TO PROVIDE PRODUCT INFORMATION AND 

ILLUSTRATE THE PRODUCTS IN THIS LITERATURE ACCURATELY; HOWEVER, SUCH INFORMATION AND ILLUSTRA-

TIONS ARE FOR THE SOLE PURPOSE OF IDENTIFICATION, AND DO NOT EXPRESS OR IMPLY A WARRANTY THAT 

THE PRODUCTS ARE MERCHANTABLE, OR FIT FOR PARTICULAR PURPOSE, OR THAT THE PRODUCTS WILL NEC-

ESSARILY CONFORM TO THE ILLUSTRATIONS OR DESCRIPTIONS. EXCEPT AS PROVIDED BELOW, NO WARRANTY 

OF AFFIRMATION OF FACT, EXPRESSED OR IMPLIED, OTHER THAT AS STATED IN THE “LIMITED WARRANTY” 

ABOVE IS MADE OR AUTHORIZED BY Global industrial.

Technical Advice and Recommendations, Disclaimer. 

Notwithstanding any past practice or dealings or trade 

custom, sales shall not include the furnishing of technical advice or assistance or system design. Global indus-

trial assumes no obligations or liability on account of any unauthorized recommendations, opinions or advice 

as to the choice, installation or use of products.

Product Suitability. 

Many jurisdictions have codes and regulations governing sales, construction, installation, 

and/or use of products for certain purposes, which may vary from those in neighboring areas. While attempts 

are made to assure that Global industrial products comply with such codes, Global industrial cannot guarantee 

compliance, and cannot be responsible for how the product is installed or used. Before purchase and use of a 

product, review the product applications, and all applicable national and local codes and regulations, and be 

sure that the product, installation, and use will comply with them.

Certain aspects of disclaimers are not applicable to consumer products; e.g., (a) some jurisdictions do not 

allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion 

may not apply to you; (b) also, some jurisdictions do not allow a limitation on how long an implied warranty 

lasts, consequently the above limitation may not apply to you; and (c) by law, during the period of this Limited 

Warranty, any implied warranties of implied merchantability or fitness for a particular purpose applicable to 

consumer products purchased by consumers, may not be excluded or otherwise disclaimed.

Prompt Disposition.

 A good faith effort will be made for prompt correction or other adjustment with the 

respect to any product which proves to be defective within limited warranty. For any product believed to be 

defective within limited warranty, first write or call dealer from whom the product was purchased. Dealer will 

give additional directions. If unable to resolve satisfactorily, write to Global industrial at the address below, 

giving dealer’s name, address, date, and number of dealer’s invoice, and describing the nature of the defect. 

Title and risk of loss pass to buyer on delivery to common carrier. If product was damaged in transit to you, 

file claim with carrier. 

Manufactured in Global industrial co., Ltd.,  11 Harbor Park Drive Port Washington, NY 11050 USA

1.888.628.3466  Customer Support   

                                                                            Printed in January, 2022

Summary of Contents for 293149

Page 1: ...l provides ease of use and con tains a self diagnostic function and display showing operating modes room and set temperatures and faults If an abnormal operation occurs a visual display of the fault i...

Page 2: ...verload protector Anti freezing thermister Full drain tank switch Automatic restart Power interruption Compressor time delay pro gram High pressure switch Features Temperature control Self diagnostic...

Page 3: ...substances to come into contact with the unit 13 DO NOT operate the unit in the presence of flammable substances or vapors such as alcohols pesticides gasoline etc 14 DO NOT use the plug to start and...

Page 4: ...ed 22 Only use in the upright position on an even flat surface Unit must be positioned at least 24 inches 60 cm from the nearest object in any direction 23 Stop operation immediately if abnormal noise...

Page 5: ...itioner as shown in Figure 4 1 Remove cool air outlet hose s from carton 2 Place the cool air outlet hose s on the front top of air conditioner 3 Use screws enclosed inside of box with cool air outlet...

Page 6: ...oreign material The unit is equipped with an approved NEMA plug configuration 292660 5 15P 292661 5 20P 292662 6 15P The appropriate outlet must be used for each plug type WARNINGS REGARDING PROPER LO...

Page 7: ...e the product Press the power button for 2 seconds while driving to stop the product Self diagnosis will be performed to test for abnormalities after marking VER for 3seconds when power is ON And the...

Page 8: ...des and operates in circulation LOW HIGH AUTOIn LCD the middle wing of each mode rotate and operate AUTO MODE If the power source becomes on after off it operates as auto and then as high or low depen...

Page 9: ...mode 1 It s the off reservation mode Press the time button for 2 seconds select the blower button and select on off minutes as the up down button You can choose to make a reservation for turning it o...

Page 10: ...in the guide and slide the filter up until the bottom of the filter clears the frame Then push the bottom of filter into the guide and let filter gently fall inside the guide NOTE For effective cooli...

Page 11: ...occurs and a code is displayed on the control panel The compressor and condenser fan motor will stop operating The evaporator fan will con tinue to run for 3 minutes If the fault is rectified within 3...

Page 12: ...rm Condensate tank is full Empty the water tank After installation of the water tank press the SPOT COOL or ROOM COOL button to resume operation Drain pump alarm Drain pump defective or improper hose...

Page 13: ...r has a loose or broken connection Contact a qualified service agent Abnormal tempera ture sensor value TH3 Prevention of Freeze Sensor open circuit or poor connection Contact a qualified service agen...

Page 14: ...2 COM L H COM L H COM CP N 1 L 1 PU PU1 CP2 COM EMC L H FUSE ALARM COM NO NC CP CP1 HP1 HP MOTOR LCD OUT TH1 LP1 LP TH2 TH3 ON OFF T AC S R FUSE TH1 TH1 OUT_TEMP SENSOR TH3 TH3 ICE_TEMP SENSOR TH2 TH...

Page 15: ...if the filter is dirty and not regularly cleaned 1 Clean the filter 2 Compressor will not work if the unit is turned off and on quickly 2 Wait 2 minutes after unit is turned off before turning the uni...

Page 16: ...inions or advice as to the choice installation or use of products Product Suitability Many jurisdictions have codes and regulations governing sales construction installation and or use of products for...