N...92
WORKSHOP MANUAL
STARTER RELAY OPERATION CHECK
7.6
0
1 / 1
page
from
2007
to
••••
© by GLOBAL GARDEN PRODUCTS
7.6 STARTER RELAY OPERATION CHECK
WARNING! – Remove the cap of the sparking
plug (or plugs), since the safety systems that
normally prevent accidental starting of the
engine are cut out when the checking procedure
is carried out.
To do this requires:
– engaging the parking brake;
– disengaging the blade;
– the key in the «ON» position.
Disconnect the connector
(1)
.
In making a bridge between the terminals 11 and 4
of the wiring connector
(1)
, the click of the relay
bobbin should be heard and the starter motor
should come into action.
➤
Only with B&S and Tecumseh engines:
If the relay clicks but the starter motor does not
go, make a bridge
(2)
with a large section cable (5
mm
2
) between the power contacts of the relay.
If the starter motor comes into operation, look for
the fault within the relay or replace it. Otherwise,
check the starter motor together with its wiring.
4/2007