10. The 10 A fuse blows
Short circuit or overload on the power
side of the electronic card (start-up
unit, starter relay) lights and recharger
connector
Find and replace the defective user [see 7.4
and 7.6]
Short circuit or damage to the elec-
tronic card protection (power side)
Try changing the card with one that is known
to work. If the problem stops, replace the
faulty card
PROBLEM
CAUSE
REMEDY
12. No audible signal for the
“grass-catcher full” con-
dition
Malfunctioning or faulty blade switch
or microswitch and grass-catcher sig-
nalling
Check the switch, the microswitch and
wiring.
WARNING! –
Check that the blade switch
stops the engine or prevents if from being
started if the acknowledgement conditions
are not met [see 7.2].
Malfunctioning or faulty electronic
card
Try changing the card with one that is known
to work. If the problem stops, replace the
faulty card.
11. The 25 A fuse blows
Faults in the battery charging circuit
Replace fuse (25 A) and check the recharge
circuit [see 7.8]