© by GLOBAL GARDEN PRODUCTS
92
7.1
.
2
- GUIDE TO THE IDENTIFICATION OF
PROBLEMS IN THE ELECTRICAL SYSTEM
3 / 3
WORKSHOP MANUAL
page
from
2006
to
••••
3/2006
11. The 6.3 A fuse blows
Short circuit or overload on the power
side of the electronic card (start-up
unit, starter relay) lights and recharger
connector
Find and replace the defective user [see 7.4
and 7.5 – 7.6]
Short circuit or damage to the elec-
tronic card protection (power side)
Try changing the card with one that is known
to work. If the problem stops, replace the
faulty card
PROBLEM
CAUSE
REMEDY
13. No audible signal for the
“grass-catcher full” con-
dition
Malfunctioning or faulty blades
microswitches and grass-catcher sig-
nalling
Check the microswitches and wiring.
WARNING!
– Check that the blade
microswitch stops the engine or prevents if
from being started if the acknowledgement
conditions are not met [see 7.2]
Malfunctioning or faulty electronic
card
Try changing the card with one that is known
to work. If the problem stops, replace the
faulty card.
12. The 25 A fuse blows
Faults in the battery charging circuit
Replace fuse (25 A) and check the recharge
circuit [see 7.8]