Glentronics PRO Series PUMPS Instruction Manual Download Page 4

 (a) The Red and Green lights should start alternating
  (b) This means the module is ready for setup

Note: In order to get your messages during a power outage, 
you will need to provide DC power to the WiFi module.  If you 
also have a Pro Series backup system, we recommend using 
the 12 volt battery providing backup power to your backup 
system (Go to 2C-8).  If you do not have a backup system, 
you must use the included 6V battery pack (Go to 2C-9)

 

8.

 If you also have a Pro Series backup sump pump

 (a) Using the 6 foot 12  
   

volt battery cable, 

   

attach the large  

   

ringlug labeled  

   

‘positive’ (+), to the  

   

positive post of  

   

the battery

 (b) 

Attach the smaller ringlug labeled negative (-) to the  

   

negative post of the battery

  (c) Plug the power jack at the  
   

other end of the wire into the  

   

12V/6V DC Battery port on the  

   

bottom of the Module

9.

 If you do not have a Pro Series  

  backup sump pump
 (a) 

Install four AA-batteries   

   

into the 6V Battery pack

  (b) Make sure the switch on   
   

the battery pack is in the  

   

‘ON’ position

  (c) Plug the battery pack into  
   

the 12V/6V DC port on the bottom of the module

2D.  Attaching your WiFi Module to your Deluxe  

    Float controller with a Remote Terminal

     

This section will explain how to connect your WiFi Module 
to your Deluxe Controller (DFC2, VSC2, TSC2 or DVSA) using 
the remote terminal and the included remote terminal 
cable.  Using the remote terminal cable will provide a 
general notification stating that your system is alarming.  
This connection style is compatible with all models that 
include a remote terminal.  

Note: This connection style should not be used if your C2 

controller is a Pro Series Connect and has a USB port.  You 
will only connect via the USB port.

1. Using the 3 foot remote terminal cable,  
  attach one end of the cable labeled ‘NO’  
  to the Normally Open port labeled ‘NO’   
  on the side of the deluxe control box.    
  Turn the screw clockwise to secure the wire.
2. On the same end of the remote terminal  
  cable, attach the cable end labeled ‘COM’ to the Common  
  port labeled ‘COM’ on the side of the deluxe control box.  
  Turn the screw clockwise to secure the wire.
3. Attach the other end of the 
  cable labeled ‘NO’ to the    
  Normally Open port labeled   
  ‘NO’ on the right side of the    
  WiFi module.  Turn the screw  
  clockwise to secure the wire.
4. On the same end of the remote terminal cable, attach  
  the cable end labeled ‘COM’ to the Common port labeled      
  ‘COM’ on the right side of the WiFi module.  Turn the  
  screw clockwise to secure the wire.
5. Connect the USB charger to the 5V DC power port of the  
  WiFi module using the included mini USB cable
6. Plug the other end of the USB charger into your power  
 outlet
7. The red and green lights on the WiFi module should  
  start alternating. This means that it is ready for setup.

Note: In order to get your messages during a power outage, 
you will need to provide DC power to the WiFi module.  If you 
also have a Pro Series backup system, we recommend using 
the 12 volt battery providing backup power to your backup 
system (Go to 2D-8).  If you do not have a backup system, 
you must use the included 6V battery pack (Go to 2D-11)

8.

 Using the 6 foot, 12  

  volt battery cable,  

  attach the large  

  ringlug labeled    

  ‘positive’ (+), to the  
  positive post of the  
 battery.

4

-

 +

-

 +

battery

pack

Summary of Contents for PRO Series PUMPS

Page 1: ...router or UPS This is a Wi Fi based device that can remotely alert the user of potential water problems in their home It will use the internal Wi Fi chip to connect to the user s Wi Fi network throug...

Page 2: ...e standard USB end into the USB port on the backup sump pump controller Note When using the data connection no other cable is necessary this cable will also power the WiFi module However we recommend...

Page 3: ...up power to your backup system 8 Using the 6 foot 12 volt battery cable attach the large ringlug labeled positive to the positive post of the battery 9 Attach the smaller ringlug labeled negative to t...

Page 4: ...a remote terminal Note This connection style should not be used if your C2 controller is a Pro Series Connect and has a USB port You will only connect via the USB port 1 Using the 3 foot remote termi...

Page 5: ...et If using in a sump or sewage pit use the included stainless steel hose clamp b Attach the wire labeled NO to the Normally Open port labeled NO on the right side of the WiFi module Turn the screw cl...

Page 6: ...is minimal buildup of water you need the following accessory a High Water Contacts HWC Available late 2018 This accessory can be ordered by calling our office at 1 800 991 0466 Once you have the part...

Page 7: ...1 1 in the URL field and hit enter go 6 Fill out the information on the setup page you may have to scroll down 7 Click the save button 8 Click on Available Networks you may have to scroll down 9 Sele...

Page 8: ...g properly c If you used the remote terminal it will indicate that the alarm has been cleared 3 You can perform this test with other alarms and you will receive an email with the corresponding notific...

Page 9: ...ds 10 Explanation of the lights This section will explain what the lights on the WiFi module mean 1 Alternating red connection error and green module status lights a The module is ready for set up 2 S...

Page 10: ...sion devices a separation distance of 20 cm or more should be maintained between the antenna of this device and persons during operation To ensure compliance operation at closer than this distance is...

Page 11: ...y or condition may last so the limitation described above may not apply to you Any and all causes of action arising from filed as a result of or in reference to this warranty or the products described...

Page 12: ...or failure to operate in accordance with the enclosed written instructions How to Obtain Warranty Service Within thirty 30 days of the product s defective performance the unit must be shipped freight...

Reviews: