D9 Wiring & Loop Interconnecting To External Equipment
9 Pin D Plug Fitted to Device
1) Loop Out 1 DIM LS
6) Loop Out 1 DIM LS
2) Loop Out 2 CUT LS
7) Loop Out 2 CUT LS
3) Input DIM LS
8) Input CUT LS
4) Input CUT INTERNAL LS (see note)
9) Spare Input
5) Ground
LOOP OUTPUT NOTE:
Internal device: Solid State Relay
Maximum current: 0.1A
Maximum voltage: 200 Volts
LOOP INPUT NOTE:
To operate connect circuit to ground
Maximum current: 3mA
High voltage level: +3.3 Volts
CUT INTERNAL LS INPUT
Making this loop does not illuminate the LED in the front panel
CUT LS switch.