Section 2.0 — Appendix / Reference
2.3 Control Head Configuration
In order for each Control Head to communicate with the Control Processor, each Control Head must have a unique Handle
Identifier. If you purchased a
complete system
, configuration and
handle identification was performed by the factory
.
If you purchased a control head
separately
, you will NEED to set the handle identifier for that control station. Follow the 8
steps below:
Move control
station handles to
FULL ASTERN
positions
No result
Turn
power ON
to the system
TAKE LED will begin to flash
All 4 LEDs begin to flash
Press & Release the
ACTIVE button one
time to select
Handle Identifier
Mode
PORT NEUTRAL LED will begin to flash
Press & HOLD the 2
center buttons
(ACTIVE & WARM)
for approximately 2
seconds until all 4
LEDs begin to flash-
RELEASE buttons
ACTION
RESULT
To Change Handle Identifier, Follow These 8 Steps:
Keypad
ON
OFF
Press & Release the
WARM button one
time to enter Handle
ID Configuration
TAKE LED will be illuminated
Chart is continued on next page . . .
1
2
3
4
5