Glenayre Document Number: 9110.00148
RL-903 Receiver
Issue 1, Rev. C: 12/10/96
MAINTENANCE
RL-903 Synthesizer Programming
Enter and run the BASIC listing using BASIC or GWBASIC. Alternatively, use this
formula:
hex number = hex(int(((fc 864.2)*160)+0.5)) where
fc = operating frequency in MHz,
int = integer function, and
hex = hexadecimal conversion function
Convert the hex number to binary using the following chart. Note that 0 = ON = blank and
1 = off = filled in.
Table 7-4 Programming Synthesizer Frequency
4or8
3or7
2or6
lor5
E
SlorS2switch
segment
setting of above switch seg-
ment
8
4
2
1
hex value
decimal value
0
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
A
10
B
11
C
12
D
13
E
14
F
15
-1 — off
-0 — ON
Date: 12/05/96
Copyright
©
1996 Glenayre
Page: 7-11